Lara Struelens

Person

Struelens, Lara

  • Research in Dosimetric Applications

Person: Employee

  1. 2020
  2. Microdosimetry at the 62 MeV Proton Beam of CATANA: preliminary comparison of three detectors

    Bianchi, A., Colautti, P., Conte, V., Selva, A., Agosteo, S., Bortot, D., Mazzucconi, D., Pola, A., Reniers, B., Parisi, A., Struelens, L., Vanhavere, F., Tran, L., Rosenfeld, A., Cirrone, P. G. A. & Petringa, G., 16 Oct 2020, In : Journal of Physics: Conference Series. 1662, p. 1-4 4 p., 012006.

    Research output: Contribution to journalArticle

  3. Nanoscale calculation of the relative efficiency of 7LiF:Mg,Ti (MTS-7) and 7LiF:Mg,Cu,P (MCP-7) thermoluminescent detectors for measuring electrons and positrons

    Parisi, A., Struelens, L. & Vanhavere, F., 16 Oct 2020, In : Journal of Physics: Conference Series. 1662, p. 1-4 4 p., 012025.

    Research output: Contribution to journalArticle

  4. Survey of chest radiography systems: Any link between contrast detail measurements and visual grading analysis?

    Rodriguez Pérez, S., W. Marshall, N., Binst, J., Coolen, J., Struelens, L. & Bosmans, H., Aug 2020, In : Physica Medica. 76, p. 62-71 10 p.

    Research output: Contribution to journalArticle

  5. Uncertainty budget assessment for the calibration of a silicon microdosimeter using the proton edge technique

    Parisi, A., Boogers, E., Struelens, L. & Vanhavere, F., 21 Jul 2020, In : Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 978, 5 p., 164449.

    Research output: Contribution to journalArticle

  6. A new method to predict the response of thermoluminescent detectors exposed at different positions within a clinical proton beam

    Parisi, A., Olko, P., Swakoń, J., Horwacik, T., Jablonski, H., Malinowski, L., Nowak, T., Struelens, L. & Vanhavere, F., 24 Feb 2020, In : Radiation Measurements. 133, p. 1-6 6 p., 106281.

    Research output: Contribution to journalArticle

  7. Cellular dosimetry of [177Lu]Lu-DOTA-[Tyr3]octreotate radionuclide therapy: the impact of modeling assumptions on the correlation with in vitro cytotoxicity

    Tamborino, G., De Saint-Hubert, M., Struelens, L., Seoane, D. C., Ruigrok, E. A. M., Aerts, A., van Cappellen, W. A., de Jong, M., Konijnenberg, M. W. & Nonnekens, J., 10 Feb 2020, In : EJNMMI Physics. 7, 8, p. 1-19 19 p.

    Research output: Contribution to journalArticle

  8. Microdosimetry with a sealed mini-TEPC and a silicon telescope at a clinical proton SOBP of CATANA

    Bianchi, A., Selva, A., Colautti, P., Bortot, D., Mazzucconi, D., Pola, A., Agosteo, S., Petringa, G., Cirrone, G. A. P., Reniers, B., Parisi, A., Struelens, L., Vanhavere, F. & Conte, V., 1 Feb 2020, In : Radiation Physics and Chemistry. 171, 108730.

    Research output: Contribution to journalArticle

  9. Mitigation of the proton-induced low temperature anomaly of LiF:Mg,Cu,P detectors using a post-irradiation pre-readout thermal protocol

    Parisi, A., Olko, P., Swakoń, J., Horwacik, T., Jabłoński, H., Malinowski, L., Nowak, T., Struelens, L. & Vanhavere, F., 21 Jan 2020, In : Radiation Measurements. 132, p. 1-6 6 p., 106233.

    Research output: Contribution to journalArticle

Previous 1 2 3 4 5 6 7 8 ...12 Next

ID: 31857