A new cylindrical phantom for eye lens dosimetry development

Research output: Contribution to journalArticlepeer-review

Standard

A new cylindrical phantom for eye lens dosimetry development. / Gualdrini, G.; Mariotti, F.; Wach, S.; Bilski, Pawel; Denozière, Marc; Daures, J.; Bordy, Jean-Marc; Ferrari, Paolo; Monteventi, F.; Fantuzzi, Elena; Vanhavere, Filip.

In: Radiation Measurements, Vol. 46, No. 11, 10.09.2011, p. 1231-1434.

Research output: Contribution to journalArticlepeer-review

Harvard

Gualdrini, G, Mariotti, F, Wach, S, Bilski, P, Denozière, M, Daures, J, Bordy, J-M, Ferrari, P, Monteventi, F, Fantuzzi, E & Vanhavere, F 2011, 'A new cylindrical phantom for eye lens dosimetry development', Radiation Measurements, vol. 46, no. 11, pp. 1231-1434. https://doi.org/10.1016/j.radmeas.2011.08.025

APA

Gualdrini, G., Mariotti, F., Wach, S., Bilski, P., Denozière, M., Daures, J., Bordy, J-M., Ferrari, P., Monteventi, F., Fantuzzi, E., & Vanhavere, F. (2011). A new cylindrical phantom for eye lens dosimetry development. Radiation Measurements, 46(11), 1231-1434. https://doi.org/10.1016/j.radmeas.2011.08.025

Vancouver

Gualdrini G, Mariotti F, Wach S, Bilski P, Denozière M, Daures J et al. A new cylindrical phantom for eye lens dosimetry development. Radiation Measurements. 2011 Sep 10;46(11):1231-1434. https://doi.org/10.1016/j.radmeas.2011.08.025

Author

Gualdrini, G. ; Mariotti, F. ; Wach, S. ; Bilski, Pawel ; Denozière, Marc ; Daures, J. ; Bordy, Jean-Marc ; Ferrari, Paolo ; Monteventi, F. ; Fantuzzi, Elena ; Vanhavere, Filip. / A new cylindrical phantom for eye lens dosimetry development. In: Radiation Measurements. 2011 ; Vol. 46, No. 11. pp. 1231-1434.

Bibtex - Download

@article{0b6ec2c25ed64da6a8c96f2c3b80f160,
title = "A new cylindrical phantom for eye lens dosimetry development",
abstract = "Due to the recent new interest of the dosimetric community generated by evidence of larger number of induced cataracts for the same absorbed dose, in the frame work of the ORAMED project (Oramed, 2008) a task was devoted to the critical revision of the eye lens dose assessment procedures. The present paper summarizes the Monte Carlo analyses carried out to optimize the Hp(3,Ω) calculations in order to produce a set of conversion coefficients Hp(3,Ω)/Ka as close as possible to those of the limiting quantity HT(eye lens)/Ka. Comparison were carried out with already published values calculated for a previous theoretical phantom, mainly suited for the calculations of Hp(10,Ω)/Ka.",
keywords = "Eye lens dosimetry, Operational quantity, Hp(3), Conversion coefficients, Monte Carlo",
author = "G. Gualdrini and F. Mariotti and S. Wach and Pawel Bilski and Marc Denozi{\`e}re and J. Daures and Jean-Marc Bordy and Paolo Ferrari and F. Monteventi and Elena Fantuzzi and Filip Vanhavere",
note = "Score=10",
year = "2011",
month = sep,
day = "10",
doi = "10.1016/j.radmeas.2011.08.025",
language = "English",
volume = "46",
pages = "1231--1434",
journal = "Radiation Measurements",
issn = "1350-4487",
publisher = "Elsevier",
number = "11",

}

RIS - Download

TY - JOUR

T1 - A new cylindrical phantom for eye lens dosimetry development

AU - Gualdrini, G.

AU - Mariotti, F.

AU - Wach, S.

AU - Bilski, Pawel

AU - Denozière, Marc

AU - Daures, J.

AU - Bordy, Jean-Marc

AU - Ferrari, Paolo

AU - Monteventi, F.

AU - Fantuzzi, Elena

AU - Vanhavere, Filip

N1 - Score=10

PY - 2011/9/10

Y1 - 2011/9/10

N2 - Due to the recent new interest of the dosimetric community generated by evidence of larger number of induced cataracts for the same absorbed dose, in the frame work of the ORAMED project (Oramed, 2008) a task was devoted to the critical revision of the eye lens dose assessment procedures. The present paper summarizes the Monte Carlo analyses carried out to optimize the Hp(3,Ω) calculations in order to produce a set of conversion coefficients Hp(3,Ω)/Ka as close as possible to those of the limiting quantity HT(eye lens)/Ka. Comparison were carried out with already published values calculated for a previous theoretical phantom, mainly suited for the calculations of Hp(10,Ω)/Ka.

AB - Due to the recent new interest of the dosimetric community generated by evidence of larger number of induced cataracts for the same absorbed dose, in the frame work of the ORAMED project (Oramed, 2008) a task was devoted to the critical revision of the eye lens dose assessment procedures. The present paper summarizes the Monte Carlo analyses carried out to optimize the Hp(3,Ω) calculations in order to produce a set of conversion coefficients Hp(3,Ω)/Ka as close as possible to those of the limiting quantity HT(eye lens)/Ka. Comparison were carried out with already published values calculated for a previous theoretical phantom, mainly suited for the calculations of Hp(10,Ω)/Ka.

KW - Eye lens dosimetry

KW - Operational quantity

KW - Hp(3)

KW - Conversion coefficients

KW - Monte Carlo

UR - https://ecm.sckcen.be/OTCS/llisapi.dll/overview/39154321

U2 - 10.1016/j.radmeas.2011.08.025

DO - 10.1016/j.radmeas.2011.08.025

M3 - Article

VL - 46

SP - 1231

EP - 1434

JO - Radiation Measurements

JF - Radiation Measurements

SN - 1350-4487

IS - 11

ER -