Anomalous results with the widely used NRPB/SSI-type passive radon dosemeter

Research output: Contribution to journalArticle

Standard

Anomalous results with the widely used NRPB/SSI-type passive radon dosemeter. / Paridaens, Johan.

In: Radiation Protection Dosimtery, Vol. 142, No. 2-4, 21.09.2010, p. 347-353.

Research output: Contribution to journalArticle

Harvard

Paridaens, J 2010, 'Anomalous results with the widely used NRPB/SSI-type passive radon dosemeter', Radiation Protection Dosimtery, vol. 142, no. 2-4, pp. 347-353.

APA

Paridaens, J. (2010). Anomalous results with the widely used NRPB/SSI-type passive radon dosemeter. Radiation Protection Dosimtery, 142(2-4), 347-353.

Vancouver

Paridaens J. Anomalous results with the widely used NRPB/SSI-type passive radon dosemeter. Radiation Protection Dosimtery. 2010 Sep 21;142(2-4):347-353.

Author

Paridaens, Johan. / Anomalous results with the widely used NRPB/SSI-type passive radon dosemeter. In: Radiation Protection Dosimtery. 2010 ; Vol. 142, No. 2-4. pp. 347-353.

Bibtex - Download

@article{5fb30e05933d4830a3291f67c8a5218c,
title = "Anomalous results with the widely used NRPB/SSI-type passive radon dosemeter",
abstract = "In an industrial hall, with large variations of radon concentration within minutes, simultaneous measurements were done with two types of passive radon detectors and an active radon measuring device. The widely used passive radon detector of the National Radiological Protection Board (NRPB) [Health Protection Agency (former NRPB) (HPA)]/Statens str{\aa}lskyddsinstitut (Swedish Radiation Protection Institute) (SSI) type produced anomalous results, seemingly uncorrelated to the radon concentration which was in the order of hundreds of becquerels per metre, usually underestimating but occasionally overestimating. We tried to reproduce similar exposure characteristics in our laboratory, but failed to reproduce the anomalous readings. We suspected, but could not prove, that the anomalous results were due to the combination of high radon concentration gradients, with pressure-driven air exchange between the inside of the detector holder and the outside atmosphere. Moreover, this theory was at least partly contradicted when we drilled holes in the detector holder. Although of interest, this effect is not likely to have substantially influenced any radon surveys, given the unusual nature of the exposure that caused the effect.",
author = "Johan Paridaens",
year = "2010",
month = "9",
day = "21",
language = "English",
volume = "142",
pages = "347--353",
journal = "Radioation Protection Dosimitry",
issn = "0144-8420",
publisher = "Oxford University Press",
number = "2-4",

}

RIS - Download

TY - JOUR

T1 - Anomalous results with the widely used NRPB/SSI-type passive radon dosemeter

AU - Paridaens, Johan

PY - 2010/9/21

Y1 - 2010/9/21

N2 - In an industrial hall, with large variations of radon concentration within minutes, simultaneous measurements were done with two types of passive radon detectors and an active radon measuring device. The widely used passive radon detector of the National Radiological Protection Board (NRPB) [Health Protection Agency (former NRPB) (HPA)]/Statens strålskyddsinstitut (Swedish Radiation Protection Institute) (SSI) type produced anomalous results, seemingly uncorrelated to the radon concentration which was in the order of hundreds of becquerels per metre, usually underestimating but occasionally overestimating. We tried to reproduce similar exposure characteristics in our laboratory, but failed to reproduce the anomalous readings. We suspected, but could not prove, that the anomalous results were due to the combination of high radon concentration gradients, with pressure-driven air exchange between the inside of the detector holder and the outside atmosphere. Moreover, this theory was at least partly contradicted when we drilled holes in the detector holder. Although of interest, this effect is not likely to have substantially influenced any radon surveys, given the unusual nature of the exposure that caused the effect.

AB - In an industrial hall, with large variations of radon concentration within minutes, simultaneous measurements were done with two types of passive radon detectors and an active radon measuring device. The widely used passive radon detector of the National Radiological Protection Board (NRPB) [Health Protection Agency (former NRPB) (HPA)]/Statens strålskyddsinstitut (Swedish Radiation Protection Institute) (SSI) type produced anomalous results, seemingly uncorrelated to the radon concentration which was in the order of hundreds of becquerels per metre, usually underestimating but occasionally overestimating. We tried to reproduce similar exposure characteristics in our laboratory, but failed to reproduce the anomalous readings. We suspected, but could not prove, that the anomalous results were due to the combination of high radon concentration gradients, with pressure-driven air exchange between the inside of the detector holder and the outside atmosphere. Moreover, this theory was at least partly contradicted when we drilled holes in the detector holder. Although of interest, this effect is not likely to have substantially influenced any radon surveys, given the unusual nature of the exposure that caused the effect.

UR - https://ecm.sckcen.be/OTCS/llisapi.dll/overview/38912770

M3 - Article

VL - 142

SP - 347

EP - 353

JO - Radioation Protection Dosimitry

JF - Radioation Protection Dosimitry

SN - 0144-8420

IS - 2-4

ER -