Characterisation of neutron fields at Cernavoda NPP

Research output: Contribution to journalArticle

Standard

Characterisation of neutron fields at Cernavoda NPP. / Cauwels, Vanessa; Vanhavere, Filip; Dumitrescu, Dorin; Chirosca, Alecsandru; Hager, Luke; Million, Marc; Bartz, James; Chiriotti Alvarez, Sabina (Peer reviewer).

In: Radiation protection dosimetry, Vol. 154, No. 1, 04.2013, p. 104-116.

Research output: Contribution to journalArticle

Harvard

Cauwels, V, Vanhavere, F, Dumitrescu, D, Chirosca, A, Hager, L, Million, M, Bartz, J & Chiriotti Alvarez, S 2013, 'Characterisation of neutron fields at Cernavoda NPP', Radiation protection dosimetry, vol. 154, no. 1, pp. 104-116. https://doi.org/10.1093/rpd/ncs135

APA

Cauwels, V., Vanhavere, F., Dumitrescu, D., Chirosca, A., Hager, L., Million, M., ... Chiriotti Alvarez, S. (2013). Characterisation of neutron fields at Cernavoda NPP. Radiation protection dosimetry, 154(1), 104-116. https://doi.org/10.1093/rpd/ncs135

Vancouver

Cauwels V, Vanhavere F, Dumitrescu D, Chirosca A, Hager L, Million M et al. Characterisation of neutron fields at Cernavoda NPP. Radiation protection dosimetry. 2013 Apr;154(1):104-116. https://doi.org/10.1093/rpd/ncs135

Author

Cauwels, Vanessa ; Vanhavere, Filip ; Dumitrescu, Dorin ; Chirosca, Alecsandru ; Hager, Luke ; Million, Marc ; Bartz, James ; Chiriotti Alvarez, Sabina. / Characterisation of neutron fields at Cernavoda NPP. In: Radiation protection dosimetry. 2013 ; Vol. 154, No. 1. pp. 104-116.

Bibtex - Download

@article{0b8ca104a5b54dbea5dda69940f31a6b,
title = "Characterisation of neutron fields at Cernavoda NPP",
abstract = "Near a nuclear reactor or a fuel container, mixed neutron/gamma fields are very common, necessitating routine neutron dosimetry. Accurate neutron dosimetry is complicated by the fact that the neutron effective dose is strongly dependent on the neutron energy and the direction distribution of the neutron fluence. Neutron field characterisation is indispensable if one wants to obtain a reliable estimate for the neutron dose. A measurement campaign at CANDU nuclear power plant located in Cernavoda, Romania, was set up to characterise the neutron fields in four different locations and to investigate the behaviour of different neutron personal dosemeters. This investigation intends to assist in choosing a suitable neutron dosimetry system at this nuclear power plant.",
keywords = "neutron fields, neutron dosimetry, neutron field characterisation",
author = "Vanessa Cauwels and Filip Vanhavere and Dorin Dumitrescu and Alecsandru Chirosca and Luke Hager and Marc Million and James Bartz and {Chiriotti Alvarez}, Sabina",
note = "Score = 10",
year = "2013",
month = "4",
doi = "10.1093/rpd/ncs135",
language = "English",
volume = "154",
pages = "104--116",
journal = "Radioation Protection Dosimitry",
issn = "0144-8420",
publisher = "Oxford University Press",
number = "1",

}

RIS - Download

TY - JOUR

T1 - Characterisation of neutron fields at Cernavoda NPP

AU - Cauwels, Vanessa

AU - Vanhavere, Filip

AU - Dumitrescu, Dorin

AU - Chirosca, Alecsandru

AU - Hager, Luke

AU - Million, Marc

AU - Bartz, James

A2 - Chiriotti Alvarez, Sabina

N1 - Score = 10

PY - 2013/4

Y1 - 2013/4

N2 - Near a nuclear reactor or a fuel container, mixed neutron/gamma fields are very common, necessitating routine neutron dosimetry. Accurate neutron dosimetry is complicated by the fact that the neutron effective dose is strongly dependent on the neutron energy and the direction distribution of the neutron fluence. Neutron field characterisation is indispensable if one wants to obtain a reliable estimate for the neutron dose. A measurement campaign at CANDU nuclear power plant located in Cernavoda, Romania, was set up to characterise the neutron fields in four different locations and to investigate the behaviour of different neutron personal dosemeters. This investigation intends to assist in choosing a suitable neutron dosimetry system at this nuclear power plant.

AB - Near a nuclear reactor or a fuel container, mixed neutron/gamma fields are very common, necessitating routine neutron dosimetry. Accurate neutron dosimetry is complicated by the fact that the neutron effective dose is strongly dependent on the neutron energy and the direction distribution of the neutron fluence. Neutron field characterisation is indispensable if one wants to obtain a reliable estimate for the neutron dose. A measurement campaign at CANDU nuclear power plant located in Cernavoda, Romania, was set up to characterise the neutron fields in four different locations and to investigate the behaviour of different neutron personal dosemeters. This investigation intends to assist in choosing a suitable neutron dosimetry system at this nuclear power plant.

KW - neutron fields

KW - neutron dosimetry

KW - neutron field characterisation

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/ezp_133293

UR - http://knowledgecentre.sckcen.be/so2/bibref/11089

U2 - 10.1093/rpd/ncs135

DO - 10.1093/rpd/ncs135

M3 - Article

VL - 154

SP - 104

EP - 116

JO - Radioation Protection Dosimitry

JF - Radioation Protection Dosimitry

SN - 0144-8420

IS - 1

ER -