Current status of individual dosimetric monitoring in Ukraine

Research output: Contribution to journalSpecial issuepeer-review

Standard

Current status of individual dosimetric monitoring in Ukraine. / Chumak, V.; Deniachenko, N.; Makrarovska, O.; Mihailescu, Cristian; Prykhodko, A.; Voloskyi, V.; Vanhavere, Filip.

In: Radiation Protection Dosimtery, Vol. 170, No. 1-4, 01.09.2016, p. 117-121.

Research output: Contribution to journalSpecial issuepeer-review

Harvard

Chumak, V, Deniachenko, N, Makrarovska, O, Mihailescu, C, Prykhodko, A, Voloskyi, V & Vanhavere, F 2016, 'Current status of individual dosimetric monitoring in Ukraine', Radiation Protection Dosimtery, vol. 170, no. 1-4, pp. 117-121. https://doi.org/10.1093/rpd/ncw038

APA

Chumak, V., Deniachenko, N., Makrarovska, O., Mihailescu, C., Prykhodko, A., Voloskyi, V., & Vanhavere, F. (2016). Current status of individual dosimetric monitoring in Ukraine. Radiation Protection Dosimtery, 170(1-4), 117-121. https://doi.org/10.1093/rpd/ncw038

Vancouver

Chumak V, Deniachenko N, Makrarovska O, Mihailescu C, Prykhodko A, Voloskyi V et al. Current status of individual dosimetric monitoring in Ukraine. Radiation Protection Dosimtery. 2016 Sep 1;170(1-4):117-121. https://doi.org/10.1093/rpd/ncw038

Author

Chumak, V. ; Deniachenko, N. ; Makrarovska, O. ; Mihailescu, Cristian ; Prykhodko, A. ; Voloskyi, V. ; Vanhavere, Filip. / Current status of individual dosimetric monitoring in Ukraine. In: Radiation Protection Dosimtery. 2016 ; Vol. 170, No. 1-4. pp. 117-121.

Bibtex - Download

@article{193715ebbc61426293c550fb02c17d52,
title = "Current status of individual dosimetric monitoring in Ukraine",
abstract = "About 50000 workers are being occupationally exposed to radiation in Ukraine. Individual dosimetric monitoring (IDM) is provided by 77 dosimetry services and laboratories of very different scale with a number of monitored workers ranging from several persons to ∼9000. In the present work, the current status of personal dosimetry in Ukraine was studied. The First National Intercomparison (FNI) of the IDM labs was accompanied by a survey of the laboratory operation in terms of coverage, types of dosimetry provided, instrumentation and methodologies used, metrological support, data recording, etc. Totally, 34 laboratories responded to the FNI call, and 18 services with 19 different personal dosimetry systems took part in the intercomparison exercise providing 24 dosemeters each for blind irradiation to photons of 6 different qualities (ISO N-series X-rays, S-Cs and S-Co sources) in a dose range of 5–60 mSv. Performance of the dosimetry labs was evaluated according to ISO 14146 criteria of matching trumpet curves with H0 5 0.2 mSv. The test revealed that 8 of the 19 systems meet ISO 14146 criteria in full, 5 other labs show marginal performance and 6 laboratories demonstrated catastrophic quality of dosimetric results. Altogether, 18 participating labs provide dosimetric monitoring to 37 477 workers (about three-fourths of all occupationally exposed workers), usually on monthly (nuclear industry) or quarterly (rest of applications) basis. Of this number, 20 664 persons (55 %) receive completely adequate individual monitoring, and the number of personnel receiving IDMof inadequate quality counts 3054 persons.",
keywords = "individual dosimetry monitoring (IDM)",
author = "V. Chumak and N. Deniachenko and O. Makrarovska and Cristian Mihailescu and A. Prykhodko and V. Voloskyi and Filip Vanhavere",
note = "Score=10; International Conference on Individual Monitoring of Ionising Radiation ; Conference date: 20-04-2015 Through 24-04-2015",
year = "2016",
month = sep,
day = "1",
doi = "10.1093/rpd/ncw038",
language = "English",
volume = "170",
pages = "117--121",
journal = "Radioation Protection Dosimitry",
issn = "0144-8420",
publisher = "Oxford University Press",
number = "1-4",

}

RIS - Download

TY - JOUR

T1 - Current status of individual dosimetric monitoring in Ukraine

AU - Chumak, V.

AU - Deniachenko, N.

AU - Makrarovska, O.

AU - Mihailescu, Cristian

AU - Prykhodko, A.

AU - Voloskyi, V.

AU - Vanhavere, Filip

N1 - Score=10

PY - 2016/9/1

Y1 - 2016/9/1

N2 - About 50000 workers are being occupationally exposed to radiation in Ukraine. Individual dosimetric monitoring (IDM) is provided by 77 dosimetry services and laboratories of very different scale with a number of monitored workers ranging from several persons to ∼9000. In the present work, the current status of personal dosimetry in Ukraine was studied. The First National Intercomparison (FNI) of the IDM labs was accompanied by a survey of the laboratory operation in terms of coverage, types of dosimetry provided, instrumentation and methodologies used, metrological support, data recording, etc. Totally, 34 laboratories responded to the FNI call, and 18 services with 19 different personal dosimetry systems took part in the intercomparison exercise providing 24 dosemeters each for blind irradiation to photons of 6 different qualities (ISO N-series X-rays, S-Cs and S-Co sources) in a dose range of 5–60 mSv. Performance of the dosimetry labs was evaluated according to ISO 14146 criteria of matching trumpet curves with H0 5 0.2 mSv. The test revealed that 8 of the 19 systems meet ISO 14146 criteria in full, 5 other labs show marginal performance and 6 laboratories demonstrated catastrophic quality of dosimetric results. Altogether, 18 participating labs provide dosimetric monitoring to 37 477 workers (about three-fourths of all occupationally exposed workers), usually on monthly (nuclear industry) or quarterly (rest of applications) basis. Of this number, 20 664 persons (55 %) receive completely adequate individual monitoring, and the number of personnel receiving IDMof inadequate quality counts 3054 persons.

AB - About 50000 workers are being occupationally exposed to radiation in Ukraine. Individual dosimetric monitoring (IDM) is provided by 77 dosimetry services and laboratories of very different scale with a number of monitored workers ranging from several persons to ∼9000. In the present work, the current status of personal dosimetry in Ukraine was studied. The First National Intercomparison (FNI) of the IDM labs was accompanied by a survey of the laboratory operation in terms of coverage, types of dosimetry provided, instrumentation and methodologies used, metrological support, data recording, etc. Totally, 34 laboratories responded to the FNI call, and 18 services with 19 different personal dosimetry systems took part in the intercomparison exercise providing 24 dosemeters each for blind irradiation to photons of 6 different qualities (ISO N-series X-rays, S-Cs and S-Co sources) in a dose range of 5–60 mSv. Performance of the dosimetry labs was evaluated according to ISO 14146 criteria of matching trumpet curves with H0 5 0.2 mSv. The test revealed that 8 of the 19 systems meet ISO 14146 criteria in full, 5 other labs show marginal performance and 6 laboratories demonstrated catastrophic quality of dosimetric results. Altogether, 18 participating labs provide dosimetric monitoring to 37 477 workers (about three-fourths of all occupationally exposed workers), usually on monthly (nuclear industry) or quarterly (rest of applications) basis. Of this number, 20 664 persons (55 %) receive completely adequate individual monitoring, and the number of personnel receiving IDMof inadequate quality counts 3054 persons.

KW - individual dosimetry monitoring (IDM)

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/27785378

U2 - 10.1093/rpd/ncw038

DO - 10.1093/rpd/ncw038

M3 - Special issue

VL - 170

SP - 117

EP - 121

JO - Radioation Protection Dosimitry

JF - Radioation Protection Dosimitry

SN - 0144-8420

IS - 1-4

T2 - International Conference on Individual Monitoring of Ionising Radiation

Y2 - 20 April 2015 through 24 April 2015

ER -