Data analysis from a multi-centre, comparative study of angiographic examinations leading to practical guidelines for the optimisation of patient doses

Research output: Contribution to journalArticle

Standard

Data analysis from a multi-centre, comparative study of angiographic examinations leading to practical guidelines for the optimisation of patient doses. / Struelens, Lara; Vanhavere, Filip; Bosmans, Hilde; Van Loon, Ronald; Geukens, Marc.

In: Radiation protection dosimetry, Vol. 117, No. special, 03.2005, p. 87-92.

Research output: Contribution to journalArticle

Author

Struelens, Lara ; Vanhavere, Filip ; Bosmans, Hilde ; Van Loon, Ronald ; Geukens, Marc. / Data analysis from a multi-centre, comparative study of angiographic examinations leading to practical guidelines for the optimisation of patient doses. In: Radiation protection dosimetry. 2005 ; Vol. 117, No. special. pp. 87-92.

Bibtex - Download

@article{4c52b549e56c43b28fe36f1d778d1800,
title = "Data analysis from a multi-centre, comparative study of angiographic examinations leading to practical guidelines for the optimisation of patient doses",
abstract = "In this study, patient doses were analysed against exposure parameters and procedure protocol. patient doses were measured in 7 hospitals for a standard diagnostic vascular examination. Image quality was assessed using the contrast-detail phantom from Nijmegen (CD-DISC 2.0). A link between dose and image quality was investigated. image qualtiy strongly depengs on the preset dose level. The higher the dose level, the better the image quality, but also the higher the patient dose. However, no clear correlation was found between total dose-area-product (DAP) or effective dose and image quality. A large range in patient dose was found: DAP (22-130 Gycm²) and effective dose (3.9-16.8 mSv). A difference in number of frames was also found in the different centres, owing to different frame rates and use of oblique projections. Differences in doses and exposure settings offer the possibility of optimising patient doses in angiography and interventional radiology.",
keywords = "optimisation, patient dose, interventional radiology",
author = "Lara Struelens and Filip Vanhavere and Hilde Bosmans and {Van Loon}, Ronald and Marc Geukens",
note = "Score = 10",
year = "2005",
month = "3",
doi = "10.1093/rpd/nci733",
language = "English",
volume = "117",
pages = "87--92",
journal = "Radioation Protection Dosimitry",
issn = "0144-8420",
publisher = "Oxford University Press",
number = "special",

}

RIS - Download

TY - JOUR

T1 - Data analysis from a multi-centre, comparative study of angiographic examinations leading to practical guidelines for the optimisation of patient doses

AU - Struelens, Lara

AU - Vanhavere, Filip

AU - Bosmans, Hilde

AU - Van Loon, Ronald

AU - Geukens, Marc

N1 - Score = 10

PY - 2005/3

Y1 - 2005/3

N2 - In this study, patient doses were analysed against exposure parameters and procedure protocol. patient doses were measured in 7 hospitals for a standard diagnostic vascular examination. Image quality was assessed using the contrast-detail phantom from Nijmegen (CD-DISC 2.0). A link between dose and image quality was investigated. image qualtiy strongly depengs on the preset dose level. The higher the dose level, the better the image quality, but also the higher the patient dose. However, no clear correlation was found between total dose-area-product (DAP) or effective dose and image quality. A large range in patient dose was found: DAP (22-130 Gycm²) and effective dose (3.9-16.8 mSv). A difference in number of frames was also found in the different centres, owing to different frame rates and use of oblique projections. Differences in doses and exposure settings offer the possibility of optimising patient doses in angiography and interventional radiology.

AB - In this study, patient doses were analysed against exposure parameters and procedure protocol. patient doses were measured in 7 hospitals for a standard diagnostic vascular examination. Image quality was assessed using the contrast-detail phantom from Nijmegen (CD-DISC 2.0). A link between dose and image quality was investigated. image qualtiy strongly depengs on the preset dose level. The higher the dose level, the better the image quality, but also the higher the patient dose. However, no clear correlation was found between total dose-area-product (DAP) or effective dose and image quality. A large range in patient dose was found: DAP (22-130 Gycm²) and effective dose (3.9-16.8 mSv). A difference in number of frames was also found in the different centres, owing to different frame rates and use of oblique projections. Differences in doses and exposure settings offer the possibility of optimising patient doses in angiography and interventional radiology.

KW - optimisation

KW - patient dose

KW - interventional radiology

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/ezp_29289

UR - http://knowledgecentre.sckcen.be/so2/bibref/3455

U2 - 10.1093/rpd/nci733

DO - 10.1093/rpd/nci733

M3 - Article

VL - 117

SP - 87

EP - 92

JO - Radioation Protection Dosimitry

JF - Radioation Protection Dosimitry

SN - 0144-8420

IS - special

ER -