Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory

Research output: Contribution to journalArticlepeer-review

Standard

Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory. / McCutcheon, Keir; Vanhaverbeke, Maarten; Pauwels, Ruben; Dabin, Jérémie; Schoonjans, Werner; Bennett, Johan; Adriaenssens, Tom; Dubois, Christophe; Sinnaeve, Peter; Desmet, Walter .

In: Circulation: Cardiovascular Interventions, Vol. 13, No. 11, e009627, 23.10.2020, p. 1-9.

Research output: Contribution to journalArticlepeer-review

Harvard

McCutcheon, K, Vanhaverbeke, M, Pauwels, R, Dabin, J, Schoonjans, W, Bennett, J, Adriaenssens, T, Dubois, C, Sinnaeve, P & Desmet, W 2020, 'Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory', Circulation: Cardiovascular Interventions, vol. 13, no. 11, e009627, pp. 1-9. https://doi.org/10.1161/CIRCINTERVENTIONS.120.009627

APA

McCutcheon, K., Vanhaverbeke, M., Pauwels, R., Dabin, J., Schoonjans, W., Bennett, J., Adriaenssens, T., Dubois, C., Sinnaeve, P., & Desmet, W. (2020). Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory. Circulation: Cardiovascular Interventions, 13(11), 1-9. [e009627]. https://doi.org/10.1161/CIRCINTERVENTIONS.120.009627

Vancouver

McCutcheon K, Vanhaverbeke M, Pauwels R, Dabin J, Schoonjans W, Bennett J et al. Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory. Circulation: Cardiovascular Interventions. 2020 Oct 23;13(11):1-9. e009627. https://doi.org/10.1161/CIRCINTERVENTIONS.120.009627

Author

McCutcheon, Keir ; Vanhaverbeke, Maarten ; Pauwels, Ruben ; Dabin, Jérémie ; Schoonjans, Werner ; Bennett, Johan ; Adriaenssens, Tom ; Dubois, Christophe ; Sinnaeve, Peter ; Desmet, Walter . / Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory. In: Circulation: Cardiovascular Interventions. 2020 ; Vol. 13, No. 11. pp. 1-9.

Bibtex - Download

@article{e148d91aed214a48a2b4fa12add7c1f7,
title = "Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory",
abstract = "BACKGROUND: Interventional cardiologists are occupationally exposed to high doses of ionizing radiation. The MAVIG X-ray protective drape (MXPD) is a commercially available light weight, lead-free shield placed over the pelvic area of patients to minimize operator radiation dose. The aim of this study was to examine the efficacy of the MXPD during routine cardiac catheterization, including percutaneous coronary interventions. METHODS: We performed a prospective, randomized controlled study comparing operator radiation dose during cardiac catheterization and percutaneous coronary intervention (n=632) with or without pelvic MXPD. We measured operator radiation dose at 4 sites: left eye, chest, left ring finger, and right ring finger. The primary outcomes were the difference in first operator radiation dose (μSv) and relative dose of the first operator (radiation dose normalized for dose area product) at the level of the chest in the 2 groups. RESULTS : The use of the MXPD was associated with a 50% reduction in operator radiation dose (median dose 30.5 [interquartile range, 23.0–39.7] μSv in no drape group versus 15.3 [interquartile range, 11.1–20.0] μSv in the drape group; P<0.001) and a 57% reduction in relative operator dose (P<0.001). The largest absolute reduction in dose was observed at the left finger (median left finger dose for the no drape group was 104.9 [75.7–137.4] μSv versus 41.9 [32.6–70.6] μSv in the drape group; P<0.001). CONCLUSIONS: The pelvic MXPD significantly reduces first operator radiation dose during routine cardiac catheterization and percutaneous coronary intervention.",
keywords = "Staff, Radiation protection, Interventional cardiology, Shielding",
author = "Keir McCutcheon and Maarten Vanhaverbeke and Ruben Pauwels and J{\'e}r{\'e}mie Dabin and Werner Schoonjans and Johan Bennett and Tom Adriaenssens and Christophe Dubois and Peter Sinnaeve and Walter Desmet",
note = "Score=10",
year = "2020",
month = oct,
day = "23",
doi = "10.1161/CIRCINTERVENTIONS.120.009627",
language = "English",
volume = "13",
pages = "1--9",
journal = "Circulation: Cardiovascular Interventions",
issn = "1941-7640",
publisher = "Lippincott, Williams & Wilkins",
number = "11",

}

RIS - Download

TY - JOUR

T1 - Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory

AU - McCutcheon, Keir

AU - Vanhaverbeke, Maarten

AU - Pauwels, Ruben

AU - Dabin, Jérémie

AU - Schoonjans, Werner

AU - Bennett, Johan

AU - Adriaenssens, Tom

AU - Dubois, Christophe

AU - Sinnaeve, Peter

AU - Desmet, Walter

N1 - Score=10

PY - 2020/10/23

Y1 - 2020/10/23

N2 - BACKGROUND: Interventional cardiologists are occupationally exposed to high doses of ionizing radiation. The MAVIG X-ray protective drape (MXPD) is a commercially available light weight, lead-free shield placed over the pelvic area of patients to minimize operator radiation dose. The aim of this study was to examine the efficacy of the MXPD during routine cardiac catheterization, including percutaneous coronary interventions. METHODS: We performed a prospective, randomized controlled study comparing operator radiation dose during cardiac catheterization and percutaneous coronary intervention (n=632) with or without pelvic MXPD. We measured operator radiation dose at 4 sites: left eye, chest, left ring finger, and right ring finger. The primary outcomes were the difference in first operator radiation dose (μSv) and relative dose of the first operator (radiation dose normalized for dose area product) at the level of the chest in the 2 groups. RESULTS : The use of the MXPD was associated with a 50% reduction in operator radiation dose (median dose 30.5 [interquartile range, 23.0–39.7] μSv in no drape group versus 15.3 [interquartile range, 11.1–20.0] μSv in the drape group; P<0.001) and a 57% reduction in relative operator dose (P<0.001). The largest absolute reduction in dose was observed at the left finger (median left finger dose for the no drape group was 104.9 [75.7–137.4] μSv versus 41.9 [32.6–70.6] μSv in the drape group; P<0.001). CONCLUSIONS: The pelvic MXPD significantly reduces first operator radiation dose during routine cardiac catheterization and percutaneous coronary intervention.

AB - BACKGROUND: Interventional cardiologists are occupationally exposed to high doses of ionizing radiation. The MAVIG X-ray protective drape (MXPD) is a commercially available light weight, lead-free shield placed over the pelvic area of patients to minimize operator radiation dose. The aim of this study was to examine the efficacy of the MXPD during routine cardiac catheterization, including percutaneous coronary interventions. METHODS: We performed a prospective, randomized controlled study comparing operator radiation dose during cardiac catheterization and percutaneous coronary intervention (n=632) with or without pelvic MXPD. We measured operator radiation dose at 4 sites: left eye, chest, left ring finger, and right ring finger. The primary outcomes were the difference in first operator radiation dose (μSv) and relative dose of the first operator (radiation dose normalized for dose area product) at the level of the chest in the 2 groups. RESULTS : The use of the MXPD was associated with a 50% reduction in operator radiation dose (median dose 30.5 [interquartile range, 23.0–39.7] μSv in no drape group versus 15.3 [interquartile range, 11.1–20.0] μSv in the drape group; P<0.001) and a 57% reduction in relative operator dose (P<0.001). The largest absolute reduction in dose was observed at the left finger (median left finger dose for the no drape group was 104.9 [75.7–137.4] μSv versus 41.9 [32.6–70.6] μSv in the drape group; P<0.001). CONCLUSIONS: The pelvic MXPD significantly reduces first operator radiation dose during routine cardiac catheterization and percutaneous coronary intervention.

KW - Staff

KW - Radiation protection

KW - Interventional cardiology

KW - Shielding

UR - https://ecm.sckcen.be/OTCS/llisapi.dll/open/42313159

U2 - 10.1161/CIRCINTERVENTIONS.120.009627

DO - 10.1161/CIRCINTERVENTIONS.120.009627

M3 - Article

VL - 13

SP - 1

EP - 9

JO - Circulation: Cardiovascular Interventions

JF - Circulation: Cardiovascular Interventions

SN - 1941-7640

IS - 11

M1 - e009627

ER -