Evaluation of physical retrospective dosimetry methods in a realistic accident scenario: Results of a field test

Research output: Contribution to journalArticlepeer-review

Standard

Evaluation of physical retrospective dosimetry methods in a realistic accident scenario: Results of a field test. / Discher, Michael; Woda, Clemens; Ekendahl, Daneila; Rojas Palma, Carlos; Steinhäusler, Friedrich.

In: Radiation Measurements, Vol. 142, 106544, 13.02.2021, p. 1-15.

Research output: Contribution to journalArticlepeer-review

Harvard

APA

Vancouver

Author

Discher, Michael ; Woda, Clemens ; Ekendahl, Daneila ; Rojas Palma, Carlos ; Steinhäusler, Friedrich. / Evaluation of physical retrospective dosimetry methods in a realistic accident scenario: Results of a field test. In: Radiation Measurements. 2021 ; Vol. 142. pp. 1-15.

Bibtex - Download

@article{9d39845649b04725962b9334b27a6139,
title = "Evaluation of physical retrospective dosimetry methods in a realistic accident scenario: Results of a field test",
abstract = "The radiological incident in Cochabamba (Bolivia 2002), where members of the general public where exposed to an unshielded Ir-192 radiation source whilst traveling on a bus was replicated here in an attempt to asses and evaluate emerging retrospective dosimetry methodologies using objects of daily life, that are either carried on or close to the human body or can be found in the vicinity of an individual. For this purpose an accidental exposure was simulated under controlled conditions in a secured area and unshielded radioactive source was placed in the cargo compartment of a bus resembling a Radiological Exposure Device (RED). Water canisters and anthropomorphic phantoms were placed at selected seats on the bus and equipped with personal objects (mobile phones, chip cards) that had reference dosimeters attached to them. At one seat position, additional salt dosimeters and dental ceramics in the phantom were also tested. Two types of 8 hour exposures were conducted: one with a source activity similar to the one in Cochabamba (0.65 TBq) and one with a stronger source (1.5 TBq) in order to have more samples with absorbed doses above the detection limit of the different methods. For 43 out of 61 resistor and glass samples from mobile phones, measured doses agreed within error limits with reference doses, but for some materials more research is needed for a more reliable application. In 13 cases outliers with a significant dose over- or underestimation were observed, 10 of these could be identified by combining the results of at least three dose assays. The field test thus evaluated the potential and limitation of retrospective dosimetry using personal objects and demonstrated the importance of using a multi-dosimeter approach to increase robustness of the method.",
keywords = "Retrospective dosimetry, Field test, Accident dosimetry, Radiological exposure device, Fortuitous materials",
author = "Michael Discher and Clemens Woda and Daneila Ekendahl and {Rojas Palma}, Carlos and Friedrich Steinh{\"a}usler",
note = "Score=10",
year = "2021",
month = feb,
day = "13",
doi = "10.1016/j.radmeas.2021.106544",
language = "English",
volume = "142",
pages = "1--15",
journal = "Radiation Measurements",
issn = "1350-4487",
publisher = "Elsevier",

}

RIS - Download

TY - JOUR

T1 - Evaluation of physical retrospective dosimetry methods in a realistic accident scenario: Results of a field test

AU - Discher, Michael

AU - Woda, Clemens

AU - Ekendahl, Daneila

AU - Rojas Palma, Carlos

AU - Steinhäusler, Friedrich

N1 - Score=10

PY - 2021/2/13

Y1 - 2021/2/13

N2 - The radiological incident in Cochabamba (Bolivia 2002), where members of the general public where exposed to an unshielded Ir-192 radiation source whilst traveling on a bus was replicated here in an attempt to asses and evaluate emerging retrospective dosimetry methodologies using objects of daily life, that are either carried on or close to the human body or can be found in the vicinity of an individual. For this purpose an accidental exposure was simulated under controlled conditions in a secured area and unshielded radioactive source was placed in the cargo compartment of a bus resembling a Radiological Exposure Device (RED). Water canisters and anthropomorphic phantoms were placed at selected seats on the bus and equipped with personal objects (mobile phones, chip cards) that had reference dosimeters attached to them. At one seat position, additional salt dosimeters and dental ceramics in the phantom were also tested. Two types of 8 hour exposures were conducted: one with a source activity similar to the one in Cochabamba (0.65 TBq) and one with a stronger source (1.5 TBq) in order to have more samples with absorbed doses above the detection limit of the different methods. For 43 out of 61 resistor and glass samples from mobile phones, measured doses agreed within error limits with reference doses, but for some materials more research is needed for a more reliable application. In 13 cases outliers with a significant dose over- or underestimation were observed, 10 of these could be identified by combining the results of at least three dose assays. The field test thus evaluated the potential and limitation of retrospective dosimetry using personal objects and demonstrated the importance of using a multi-dosimeter approach to increase robustness of the method.

AB - The radiological incident in Cochabamba (Bolivia 2002), where members of the general public where exposed to an unshielded Ir-192 radiation source whilst traveling on a bus was replicated here in an attempt to asses and evaluate emerging retrospective dosimetry methodologies using objects of daily life, that are either carried on or close to the human body or can be found in the vicinity of an individual. For this purpose an accidental exposure was simulated under controlled conditions in a secured area and unshielded radioactive source was placed in the cargo compartment of a bus resembling a Radiological Exposure Device (RED). Water canisters and anthropomorphic phantoms were placed at selected seats on the bus and equipped with personal objects (mobile phones, chip cards) that had reference dosimeters attached to them. At one seat position, additional salt dosimeters and dental ceramics in the phantom were also tested. Two types of 8 hour exposures were conducted: one with a source activity similar to the one in Cochabamba (0.65 TBq) and one with a stronger source (1.5 TBq) in order to have more samples with absorbed doses above the detection limit of the different methods. For 43 out of 61 resistor and glass samples from mobile phones, measured doses agreed within error limits with reference doses, but for some materials more research is needed for a more reliable application. In 13 cases outliers with a significant dose over- or underestimation were observed, 10 of these could be identified by combining the results of at least three dose assays. The field test thus evaluated the potential and limitation of retrospective dosimetry using personal objects and demonstrated the importance of using a multi-dosimeter approach to increase robustness of the method.

KW - Retrospective dosimetry

KW - Field test

KW - Accident dosimetry

KW - Radiological exposure device

KW - Fortuitous materials

UR - https://ecm.sckcen.be/OTCS/llisapi.dll/open/42312451

U2 - 10.1016/j.radmeas.2021.106544

DO - 10.1016/j.radmeas.2021.106544

M3 - Article

VL - 142

SP - 1

EP - 15

JO - Radiation Measurements

JF - Radiation Measurements

SN - 1350-4487

M1 - 106544

ER -

ID: 7044184