Intercomparison of Gafchromic™ films, TL detectors and TL foils for the measurements of skin dose in interventional radiology

Research output: Contribution to journalArticlepeer-review

Standard

Intercomparison of Gafchromic™ films, TL detectors and TL foils for the measurements of skin dose in interventional radiology. / Kopec, R; Novak, L; Carinou, E; Clairand, I; Dabin, Jérémie; Datz, H; De Angelis, C; Farah, J; Huet, C; Knezevic, Z; Jarvinen, H; Majer, M; Malchair, F; Negri, A; Haruz Waschitz, S; Siiskonen, T; Szumska, A; Trianni, A; Vanhavere, Filip.

In: Radiation Measurements, Vol. 71, No. 12, 12.2014, p. 282-286.

Research output: Contribution to journalArticlepeer-review

Harvard

Kopec, R, Novak, L, Carinou, E, Clairand, I, Dabin, J, Datz, H, De Angelis, C, Farah, J, Huet, C, Knezevic, Z, Jarvinen, H, Majer, M, Malchair, F, Negri, A, Haruz Waschitz, S, Siiskonen, T, Szumska, A, Trianni, A & Vanhavere, F 2014, 'Intercomparison of Gafchromic™ films, TL detectors and TL foils for the measurements of skin dose in interventional radiology', Radiation Measurements, vol. 71, no. 12, pp. 282-286. https://doi.org/10.1016/j.radmeas.2014.04.008

APA

Kopec, R., Novak, L., Carinou, E., Clairand, I., Dabin, J., Datz, H., De Angelis, C., Farah, J., Huet, C., Knezevic, Z., Jarvinen, H., Majer, M., Malchair, F., Negri, A., Haruz Waschitz, S., Siiskonen, T., Szumska, A., Trianni, A., & Vanhavere, F. (2014). Intercomparison of Gafchromic™ films, TL detectors and TL foils for the measurements of skin dose in interventional radiology. Radiation Measurements, 71(12), 282-286. https://doi.org/10.1016/j.radmeas.2014.04.008

Author

Kopec, R ; Novak, L ; Carinou, E ; Clairand, I ; Dabin, Jérémie ; Datz, H ; De Angelis, C ; Farah, J ; Huet, C ; Knezevic, Z ; Jarvinen, H ; Majer, M ; Malchair, F ; Negri, A ; Haruz Waschitz, S ; Siiskonen, T ; Szumska, A ; Trianni, A ; Vanhavere, Filip. / Intercomparison of Gafchromic™ films, TL detectors and TL foils for the measurements of skin dose in interventional radiology. In: Radiation Measurements. 2014 ; Vol. 71, No. 12. pp. 282-286.

Bibtex - Download

@article{532c061357484b0ba4d8259a909bfc60,
title = "Intercomparison of Gafchromic{\texttrademark} films, TL detectors and TL foils for the measurements of skin dose in interventional radiology",
abstract = "The energy response of gafchromic films and different kinds of thermoluminescence (TL) dosimeters were studied. Detectors were exposed to various beam qualities. After laboratory studies, detectors were used in hospitals to determine maximum skin dose (MSD) during clinical interventional radiology (IR) procedures. It was observed that the calibration process of Gafchromic films could introduce significant uncertainties in MSD measurement mainly due to energy and non-linear dose response. TL detectors were able to measure dose with lower uncertainty. However, the use of TL detectors is more time-consuming and the location of the MSD on the patient can be missed. Measurements performed with TL foils lead to good agreement in “high” dose range (several hundreds of mGy). TL foils could represent the most adapted tool for the assessment of fluoroscopy-induced skin doses. However, since they are not commercially available nowadays their application in clinical practice is limited.",
keywords = "Maximum skin dose in interventional radiology, MSD in IR, Gafchromic films, Thermoluminescence detectors",
author = "R Kopec and L Novak and E Carinou and I Clairand and J{\'e}r{\'e}mie Dabin and H Datz and {De Angelis}, C and J Farah and C Huet and Z Knezevic and H Jarvinen and M Majer and F Malchair and A Negri and {Haruz Waschitz}, S and T Siiskonen and A Szumska and A Trianni and Filip Vanhavere",
note = "Score = 10; 17th Solid State Dosimetry Conference (SSD17) ; Conference date: 22-09-2013 Through 27-09-2013",
year = "2014",
month = dec,
doi = "10.1016/j.radmeas.2014.04.008",
language = "English",
volume = "71",
pages = "282--286",
journal = "Radiation Measurements",
issn = "1350-4487",
publisher = "Elsevier",
number = "12",

}

RIS - Download

TY - JOUR

T1 - Intercomparison of Gafchromic™ films, TL detectors and TL foils for the measurements of skin dose in interventional radiology

AU - Kopec, R

AU - Novak, L

AU - Carinou, E

AU - Clairand, I

AU - Dabin, Jérémie

AU - Datz, H

AU - De Angelis, C

AU - Farah, J

AU - Huet, C

AU - Knezevic, Z

AU - Jarvinen, H

AU - Majer, M

AU - Malchair, F

AU - Negri, A

AU - Haruz Waschitz, S

AU - Siiskonen, T

AU - Szumska, A

AU - Trianni, A

AU - Vanhavere, Filip

N1 - Score = 10

PY - 2014/12

Y1 - 2014/12

N2 - The energy response of gafchromic films and different kinds of thermoluminescence (TL) dosimeters were studied. Detectors were exposed to various beam qualities. After laboratory studies, detectors were used in hospitals to determine maximum skin dose (MSD) during clinical interventional radiology (IR) procedures. It was observed that the calibration process of Gafchromic films could introduce significant uncertainties in MSD measurement mainly due to energy and non-linear dose response. TL detectors were able to measure dose with lower uncertainty. However, the use of TL detectors is more time-consuming and the location of the MSD on the patient can be missed. Measurements performed with TL foils lead to good agreement in “high” dose range (several hundreds of mGy). TL foils could represent the most adapted tool for the assessment of fluoroscopy-induced skin doses. However, since they are not commercially available nowadays their application in clinical practice is limited.

AB - The energy response of gafchromic films and different kinds of thermoluminescence (TL) dosimeters were studied. Detectors were exposed to various beam qualities. After laboratory studies, detectors were used in hospitals to determine maximum skin dose (MSD) during clinical interventional radiology (IR) procedures. It was observed that the calibration process of Gafchromic films could introduce significant uncertainties in MSD measurement mainly due to energy and non-linear dose response. TL detectors were able to measure dose with lower uncertainty. However, the use of TL detectors is more time-consuming and the location of the MSD on the patient can be missed. Measurements performed with TL foils lead to good agreement in “high” dose range (several hundreds of mGy). TL foils could represent the most adapted tool for the assessment of fluoroscopy-induced skin doses. However, since they are not commercially available nowadays their application in clinical practice is limited.

KW - Maximum skin dose in interventional radiology

KW - MSD in IR

KW - Gafchromic films

KW - Thermoluminescence detectors

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/ezp_138253

UR - http://knowledgecentre.sckcen.be/so2/bibref/12249

U2 - 10.1016/j.radmeas.2014.04.008