LIMETS 3, a novel system for high strain fatigue testing in lead-bismuth eutectic

Research output: Contribution to journalArticle

Standard

LIMETS 3, a novel system for high strain fatigue testing in lead-bismuth eutectic. / Marmy, Pierre; Gong, Xing; Gavrilov, Serguei (Peer reviewer).

In: Journal of Nuclear Materials, Vol. 450, No. 1-3, 15.01.2014, p. 256-261.

Research output: Contribution to journalArticle

Author

Bibtex - Download

@article{6434600cfc044dc8885fb39acab2aff7,
title = "LIMETS 3, a novel system for high strain fatigue testing in lead-bismuth eutectic",
abstract = "The LIMETS 3 high strain fatigue testing set up is equipped with a mechanical extensometer capable of measuring accurately the strain on teh specimen gauge length and a gas conditionning loop to control the LBE oxygen content in a fixed range. The first results obtaind in LBE at 300,350 and 400 °C with the ferritic martensitic steel T91 and the austenitic steel 316L are presented together with results obtained in air at room temperature.",
keywords = "LBE, fatigue test set up, T91, 316L",
author = "Pierre Marmy and Xing Gong and Serguei Gavrilov",
note = "Score = 10",
year = "2014",
month = "1",
day = "15",
doi = "10.1016/j.jnucmat.2013.10.064",
language = "English",
volume = "450",
pages = "256--261",
journal = "Journal of Nuclear Materials",
issn = "0022-3115",
publisher = "Elsevier",
number = "1-3",

}

RIS - Download

TY - JOUR

T1 - LIMETS 3, a novel system for high strain fatigue testing in lead-bismuth eutectic

AU - Marmy, Pierre

AU - Gong, Xing

A2 - Gavrilov, Serguei

N1 - Score = 10

PY - 2014/1/15

Y1 - 2014/1/15

N2 - The LIMETS 3 high strain fatigue testing set up is equipped with a mechanical extensometer capable of measuring accurately the strain on teh specimen gauge length and a gas conditionning loop to control the LBE oxygen content in a fixed range. The first results obtaind in LBE at 300,350 and 400 °C with the ferritic martensitic steel T91 and the austenitic steel 316L are presented together with results obtained in air at room temperature.

AB - The LIMETS 3 high strain fatigue testing set up is equipped with a mechanical extensometer capable of measuring accurately the strain on teh specimen gauge length and a gas conditionning loop to control the LBE oxygen content in a fixed range. The first results obtaind in LBE at 300,350 and 400 °C with the ferritic martensitic steel T91 and the austenitic steel 316L are presented together with results obtained in air at room temperature.

KW - LBE

KW - fatigue test set up

KW - T91

KW - 316L

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/ezp_139447

UR - http://knowledgecentre.sckcen.be/so2/bibref/12593

U2 - 10.1016/j.jnucmat.2013.10.064

DO - 10.1016/j.jnucmat.2013.10.064

M3 - Article

VL - 450

SP - 256

EP - 261

JO - Journal of Nuclear Materials

JF - Journal of Nuclear Materials

SN - 0022-3115

IS - 1-3

ER -

ID: 92573