Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project

Research output: Contribution to journalArticle

Standard

Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project. / Vanhavere, Filip; Carinou, E.; Domienik, J.; Donadille, L.; Ginjaume, M.; Gualdrini, G.; Koukorava, C.; Krim, Sabah; Nikodemova, D.; Ruiz-Lopez, N.; Sans-Merce, M.; Struelens, Lara.

In: Radiation Measurements, Vol. 46, No. 11, 12.2011, p. 1243-1247.

Research output: Contribution to journalArticle

Harvard

Vanhavere, F, Carinou, E, Domienik, J, Donadille, L, Ginjaume, M, Gualdrini, G, Koukorava, C, Krim, S, Nikodemova, D, Ruiz-Lopez, N, Sans-Merce, M & Struelens, L 2011, 'Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project', Radiation Measurements, vol. 46, no. 11, pp. 1243-1247. https://doi.org/10.1016/j.radmeas.2011.08.013

APA

Vanhavere, F., Carinou, E., Domienik, J., Donadille, L., Ginjaume, M., Gualdrini, G., ... Struelens, L. (2011). Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project. Radiation Measurements, 46(11), 1243-1247. https://doi.org/10.1016/j.radmeas.2011.08.013

Vancouver

Vanhavere F, Carinou E, Domienik J, Donadille L, Ginjaume M, Gualdrini G et al. Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project. Radiation Measurements. 2011 Dec;46(11):1243-1247. https://doi.org/10.1016/j.radmeas.2011.08.013

Author

Vanhavere, Filip ; Carinou, E. ; Domienik, J. ; Donadille, L. ; Ginjaume, M. ; Gualdrini, G. ; Koukorava, C. ; Krim, Sabah ; Nikodemova, D. ; Ruiz-Lopez, N. ; Sans-Merce, M. ; Struelens, Lara. / Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project. In: Radiation Measurements. 2011 ; Vol. 46, No. 11. pp. 1243-1247.

Bibtex - Download

@article{1efc9f828600473ebf6bbcf06019855b,
title = "Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project",
abstract = "Within the ORAMED project (Optimization of Radiation Protection of Medical Staff) a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe (www.oramed-fp7.eu). The main objective was to obtain a set of standardized data on extremity and eye lens doses for staff involved in interventional radiology and cardiology and to optimize radiation protection. Special attention was given to the measurement of the doses to the eye lenses. In this paper an overview will be given of the measured eye lens doses and the main influence factors for these doses. The measured eye lens doses are extrapolated to annual doses. The extrapolations showed that monitoring of the eye lens should be performed on routine basis.",
keywords = "Interventional radiology, eye lens dosimetry, thermoluminescent detectors",
author = "Filip Vanhavere and E. Carinou and J. Domienik and L. Donadille and M. Ginjaume and G. Gualdrini and C. Koukorava and Sabah Krim and D. Nikodemova and N. Ruiz-Lopez and M. Sans-Merce and Lara Struelens",
note = "Score = 10",
year = "2011",
month = "12",
doi = "10.1016/j.radmeas.2011.08.013",
language = "English",
volume = "46",
pages = "1243--1247",
journal = "Radiation Measurements",
issn = "1350-4487",
publisher = "Elsevier",
number = "11",

}

RIS - Download

TY - JOUR

T1 - Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project

AU - Vanhavere, Filip

AU - Carinou, E.

AU - Domienik, J.

AU - Donadille, L.

AU - Ginjaume, M.

AU - Gualdrini, G.

AU - Koukorava, C.

AU - Krim, Sabah

AU - Nikodemova, D.

AU - Ruiz-Lopez, N.

AU - Sans-Merce, M.

AU - Struelens, Lara

N1 - Score = 10

PY - 2011/12

Y1 - 2011/12

N2 - Within the ORAMED project (Optimization of Radiation Protection of Medical Staff) a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe (www.oramed-fp7.eu). The main objective was to obtain a set of standardized data on extremity and eye lens doses for staff involved in interventional radiology and cardiology and to optimize radiation protection. Special attention was given to the measurement of the doses to the eye lenses. In this paper an overview will be given of the measured eye lens doses and the main influence factors for these doses. The measured eye lens doses are extrapolated to annual doses. The extrapolations showed that monitoring of the eye lens should be performed on routine basis.

AB - Within the ORAMED project (Optimization of Radiation Protection of Medical Staff) a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe (www.oramed-fp7.eu). The main objective was to obtain a set of standardized data on extremity and eye lens doses for staff involved in interventional radiology and cardiology and to optimize radiation protection. Special attention was given to the measurement of the doses to the eye lenses. In this paper an overview will be given of the measured eye lens doses and the main influence factors for these doses. The measured eye lens doses are extrapolated to annual doses. The extrapolations showed that monitoring of the eye lens should be performed on routine basis.

KW - Interventional radiology

KW - eye lens dosimetry

KW - thermoluminescent detectors

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/ezp_118376

UR - http://knowledgecentre.sckcen.be/so2/bibref/8745

U2 - 10.1016/j.radmeas.2011.08.013

DO - 10.1016/j.radmeas.2011.08.013

M3 - Article

VL - 46

SP - 1243

EP - 1247

JO - Radiation Measurements

JF - Radiation Measurements

SN - 1350-4487

IS - 11

ER -

ID: 213602