Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor

Research output: Contribution to journalArticle

Standard

Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor. / Colautti, Paolo; Moro, Davide; Chiriotti Alvarez, Sabina; Conte, Valeria; Evangelista, Laura; Altieri, Saverio; Bortolussi, Silvia; Protti, Nicoletta; Postuma, Ian; Vanhavere, Filip (Peer reviewer); D'Agostino, Emiliano (Peer reviewer).

In: Applied Radiation and Isotopes, Vol. 88, 22.01.2014, p. 147-152.

Research output: Contribution to journalArticle

Harvard

Colautti, P, Moro, D, Chiriotti Alvarez, S, Conte, V, Evangelista, L, Altieri, S, Bortolussi, S, Protti, N, Postuma, I, Vanhavere, F & D'Agostino, E 2014, 'Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor', Applied Radiation and Isotopes, vol. 88, pp. 147-152. https://doi.org/10.1016/j.apradiso.2014.01.005

APA

Colautti, P., Moro, D., Chiriotti Alvarez, S., Conte, V., Evangelista, L., Altieri, S., ... D'Agostino, E. (2014). Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor. Applied Radiation and Isotopes, 88, 147-152. https://doi.org/10.1016/j.apradiso.2014.01.005

Vancouver

Colautti P, Moro D, Chiriotti Alvarez S, Conte V, Evangelista L, Altieri S et al. Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor. Applied Radiation and Isotopes. 2014 Jan 22;88:147-152. https://doi.org/10.1016/j.apradiso.2014.01.005

Author

Colautti, Paolo ; Moro, Davide ; Chiriotti Alvarez, Sabina ; Conte, Valeria ; Evangelista, Laura ; Altieri, Saverio ; Bortolussi, Silvia ; Protti, Nicoletta ; Postuma, Ian ; Vanhavere, Filip ; D'Agostino, Emiliano. / Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor. In: Applied Radiation and Isotopes. 2014 ; Vol. 88. pp. 147-152.

Bibtex - Download

@article{c90fa470cc1c415481e76fb4205b368e,
title = "Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor",
abstract = "A twin TEPC with electric-field guard tubes has been constructed to be used to characterize the BNCT field of the irradiation facility of LENA reactor. One of the two mini TEPC was doped with 50 ppm of 10B in order to simulate the BNC events occurring in BNCT. By properly processing the two microdosimetric spectra, the gamma, neutron and BNC spectral components can be derived with good precision (~6{\%}). However, direct measurements of 10B in some doped plastic samples, which were used for contructing the cathod walls, point out the scarce accuracy of the nominal 10B concentration value. The influence of the Boral door, which closes the irradiation channel, has been measured. The gamma dose increases significantly (+ 51{\%}) when the Boral{\circledR} door is closed. The crypt-cell-regeneration weighting function has been used to measure the quality, namely the RBEµ-value, of the radiation field in different conditions. The measured RBEµ values are only partially consistent with RBE values of other BNCT facilities",
keywords = "Twin TEPC, microdosimetry, BNCT",
author = "Paolo Colautti and Davide Moro and {Chiriotti Alvarez}, Sabina and Valeria Conte and Laura Evangelista and Saverio Altieri and Silvia Bortolussi and Nicoletta Protti and Ian Postuma and Filip Vanhavere and Emiliano D'Agostino",
note = "Score = 10",
year = "2014",
month = "1",
day = "22",
doi = "10.1016/j.apradiso.2014.01.005",
language = "English",
volume = "88",
pages = "147--152",
journal = "Applied Radiation and Isotopes",
issn = "0969-8043",
publisher = "Elsevier",

}

RIS - Download

TY - JOUR

T1 - Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor

AU - Colautti, Paolo

AU - Moro, Davide

AU - Chiriotti Alvarez, Sabina

AU - Conte, Valeria

AU - Evangelista, Laura

AU - Altieri, Saverio

AU - Bortolussi, Silvia

AU - Protti, Nicoletta

AU - Postuma, Ian

A2 - Vanhavere, Filip

A2 - D'Agostino, Emiliano

N1 - Score = 10

PY - 2014/1/22

Y1 - 2014/1/22

N2 - A twin TEPC with electric-field guard tubes has been constructed to be used to characterize the BNCT field of the irradiation facility of LENA reactor. One of the two mini TEPC was doped with 50 ppm of 10B in order to simulate the BNC events occurring in BNCT. By properly processing the two microdosimetric spectra, the gamma, neutron and BNC spectral components can be derived with good precision (~6%). However, direct measurements of 10B in some doped plastic samples, which were used for contructing the cathod walls, point out the scarce accuracy of the nominal 10B concentration value. The influence of the Boral door, which closes the irradiation channel, has been measured. The gamma dose increases significantly (+ 51%) when the Boral® door is closed. The crypt-cell-regeneration weighting function has been used to measure the quality, namely the RBEµ-value, of the radiation field in different conditions. The measured RBEµ values are only partially consistent with RBE values of other BNCT facilities

AB - A twin TEPC with electric-field guard tubes has been constructed to be used to characterize the BNCT field of the irradiation facility of LENA reactor. One of the two mini TEPC was doped with 50 ppm of 10B in order to simulate the BNC events occurring in BNCT. By properly processing the two microdosimetric spectra, the gamma, neutron and BNC spectral components can be derived with good precision (~6%). However, direct measurements of 10B in some doped plastic samples, which were used for contructing the cathod walls, point out the scarce accuracy of the nominal 10B concentration value. The influence of the Boral door, which closes the irradiation channel, has been measured. The gamma dose increases significantly (+ 51%) when the Boral® door is closed. The crypt-cell-regeneration weighting function has been used to measure the quality, namely the RBEµ-value, of the radiation field in different conditions. The measured RBEµ values are only partially consistent with RBE values of other BNCT facilities

KW - Twin TEPC

KW - microdosimetry

KW - BNCT

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/ezp_133238

UR - http://knowledgecentre.sckcen.be/so2/bibref/11263

U2 - 10.1016/j.apradiso.2014.01.005

DO - 10.1016/j.apradiso.2014.01.005

M3 - Article

VL - 88

SP - 147

EP - 152

JO - Applied Radiation and Isotopes

JF - Applied Radiation and Isotopes

SN - 0969-8043

ER -