Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison

Research output: Contribution to journalArticle

Standard

Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison. / Broggio, David; Bento, J.; Caldeira, M.; Cardenas-Mendez, E.; Farah, J.; Fonseca, Telma; Lebacq, Anne Laure; Mihailescu, Cristian; Vanhavere, Filip; et al. ; Malambu Mbala, Edouard (Peer reviewer).

In: Radiation Measurements, Vol. 47, No. 7, 24.04.2012, p. 492-500.

Research output: Contribution to journalArticle

Vancouver

Broggio D, Bento J, Caldeira M, Cardenas-Mendez E, Farah J, Fonseca T et al. Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison. Radiation Measurements. 2012 Apr 24;47(7):492-500. https://doi.org/10.1016/j.radmeas.2012.04.020

Author

Broggio, David ; Bento, J. ; Caldeira, M. ; Cardenas-Mendez, E. ; Farah, J. ; Fonseca, Telma ; Lebacq, Anne Laure ; Mihailescu, Cristian ; Vanhavere, Filip ; et al. ; Malambu Mbala, Edouard. / Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison. In: Radiation Measurements. 2012 ; Vol. 47, No. 7. pp. 492-500.

Bibtex - Download

@article{9a9ba0000c2a4bd08d7b9f10701edf43,
title = "Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison",
abstract = "In order to assess the reliability of Monte Carlo (MC)-based numerical calibration of in vivo counting systems the EURADOS network supported a comparison of MC simulation of well-defined experiments. This action also provided training for the use of voxel phantoms. In vivo measurements of enriched uranium in a thoracic phantom have been carried out and the needed information to simulate these measurements was distributed to 17 participants. About half of the participants managed to simulate the measured counting efficiency without support from the organisers. Following additional support all participants managed to simulate the counting efficiencies within a typical agreement of +-5{\%} with experiment.",
keywords = "In vivo measurements Monte Carlo computation Internal dosimetry Worker monitoring Intercomparison",
author = "David Broggio and J. Bento and M. Caldeira and E. Cardenas-Mendez and J. Farah and Telma Fonseca and Lebacq, {Anne Laure} and Cristian Mihailescu and Filip Vanhavere and {et al.} and {Malambu Mbala}, Edouard",
note = "Score = 10",
year = "2012",
month = "4",
day = "24",
doi = "10.1016/j.radmeas.2012.04.020",
language = "English",
volume = "47",
pages = "492--500",
journal = "Radiation Measurements",
issn = "1350-4487",
publisher = "Elsevier",
number = "7",

}

RIS - Download

TY - JOUR

T1 - Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison

AU - Broggio, David

AU - Bento, J.

AU - Caldeira, M.

AU - Cardenas-Mendez, E.

AU - Farah, J.

AU - Fonseca, Telma

AU - Lebacq, Anne Laure

AU - Mihailescu, Cristian

AU - Vanhavere, Filip

AU - et al.

A2 - Malambu Mbala, Edouard

N1 - Score = 10

PY - 2012/4/24

Y1 - 2012/4/24

N2 - In order to assess the reliability of Monte Carlo (MC)-based numerical calibration of in vivo counting systems the EURADOS network supported a comparison of MC simulation of well-defined experiments. This action also provided training for the use of voxel phantoms. In vivo measurements of enriched uranium in a thoracic phantom have been carried out and the needed information to simulate these measurements was distributed to 17 participants. About half of the participants managed to simulate the measured counting efficiency without support from the organisers. Following additional support all participants managed to simulate the counting efficiencies within a typical agreement of +-5% with experiment.

AB - In order to assess the reliability of Monte Carlo (MC)-based numerical calibration of in vivo counting systems the EURADOS network supported a comparison of MC simulation of well-defined experiments. This action also provided training for the use of voxel phantoms. In vivo measurements of enriched uranium in a thoracic phantom have been carried out and the needed information to simulate these measurements was distributed to 17 participants. About half of the participants managed to simulate the measured counting efficiency without support from the organisers. Following additional support all participants managed to simulate the counting efficiencies within a typical agreement of +-5% with experiment.

KW - In vivo measurements Monte Carlo computation Internal dosimetry Worker monitoring Intercomparison

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/ezp_122135

UR - http://knowledgecentre.sckcen.be/so2/bibref/9343

U2 - 10.1016/j.radmeas.2012.04.020

DO - 10.1016/j.radmeas.2012.04.020

M3 - Article

VL - 47

SP - 492

EP - 500

JO - Radiation Measurements

JF - Radiation Measurements

SN - 1350-4487

IS - 7

ER -