abstract = "During the exploitation of CALLISTO, the radiological activity inside the loop increases continuously causing high dose rates for personnel. A chemical decontamination of CALLISTO is necessary to reduce the dose rates. This study covers several aspects. First there is the need for a thorough research concerning the used method of decontamination. There is decided to use an adapted variant of the CORD (Chemical Oxidation Reduction Decontamination) method based on different deliberate arguments like the requirement for limited aggressiveness of the decontaminating chemicals. The loop has to keep its full integrity after decontamination, so the chemicals can’t be too aggressive. The second part comprises an analysis of different technical designs for the decontamination installation. Important is the provision of a thorough shielding. The installation will contain a lot of activated material after the completion of the decontamination process. The waste problem will also be discussed. Another important aspect concerns the connection of the decontamination installation to CALLISTO. We suggest to exclude certain parts of CALLISTO during the decontamination process to prevent non-contaminated parts to become contaminated. When designing the installation, the volume of the installation and the available space in the reactor building are two other factors asking for attention.",
keywords = "Decontamination, CALLISTO, CORD, BR2",
author = "Werner Brouwers and Dirk Vanleeuw",
note = "Score = 2",
year = "2007",
month = "5",
day = "15",
language = "English",
publisher = "PXL - Hogeschool PXL",
school = "PXL - Hogeschool PXL",

}

RIS - Download

TY - THES

T1 - Nucleaire ontsmetting van CALLISTO, een experimentele kringloop in de BR2 testreactor

AU - Brouwers, Werner

A2 - Vanleeuw, Dirk

N1 - Score = 2

PY - 2007/5/15

Y1 - 2007/5/15

N2 - During the exploitation of CALLISTO, the radiological activity inside the loop increases continuously causing high dose rates for personnel. A chemical decontamination of CALLISTO is necessary to reduce the dose rates. This study covers several aspects. First there is the need for a thorough research concerning the used method of decontamination. There is decided to use an adapted variant of the CORD (Chemical Oxidation Reduction Decontamination) method based on different deliberate arguments like the requirement for limited aggressiveness of the decontaminating chemicals. The loop has to keep its full integrity after decontamination, so the chemicals can’t be too aggressive. The second part comprises an analysis of different technical designs for the decontamination installation. Important is the provision of a thorough shielding. The installation will contain a lot of activated material after the completion of the decontamination process. The waste problem will also be discussed. Another important aspect concerns the connection of the decontamination installation to CALLISTO. We suggest to exclude certain parts of CALLISTO during the decontamination process to prevent non-contaminated parts to become contaminated. When designing the installation, the volume of the installation and the available space in the reactor building are two other factors asking for attention.

AB - During the exploitation of CALLISTO, the radiological activity inside the loop increases continuously causing high dose rates for personnel. A chemical decontamination of CALLISTO is necessary to reduce the dose rates. This study covers several aspects. First there is the need for a thorough research concerning the used method of decontamination. There is decided to use an adapted variant of the CORD (Chemical Oxidation Reduction Decontamination) method based on different deliberate arguments like the requirement for limited aggressiveness of the decontaminating chemicals. The loop has to keep its full integrity after decontamination, so the chemicals can’t be too aggressive. The second part comprises an analysis of different technical designs for the decontamination installation. Important is the provision of a thorough shielding. The installation will contain a lot of activated material after the completion of the decontamination process. The waste problem will also be discussed. Another important aspect concerns the connection of the decontamination installation to CALLISTO. We suggest to exclude certain parts of CALLISTO during the decontamination process to prevent non-contaminated parts to become contaminated. When designing the installation, the volume of the installation and the available space in the reactor building are two other factors asking for attention.

KW - Decontamination

KW - CALLISTO

KW - CORD

KW - BR2

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/ezp_85255

M3 - Master's thesis

PB - PXL - Hogeschool PXL

CY - Diepenbeek,, Belgium

ER -

ID: 355510