Abstract

ITER has diagnostics with machine protection, basic and advanced control, and physics roles. Several are distributed on the inner and outer periphery of the vacuum vessel. They have reduced maintainability compared to diagnostics in ports. They also endure some of the highest nuclear and EM loads of any diagnostic for the longest time. They include: - Inductive sensors for time-integrated and raw inductive measurements; - Steady-state magnetic sensors to correct drifts of the inductive sensors; - Bolometer cameras to provide electromagnetic radiation tomography; - Microfission chambers and neutron activation stations to provide fusion power and fluence; - MM-wave reflectometry to measure the plasma density profile and the plasma-wall distance and; - Wiring to service magnetics, bolometry, and in-vessel instrumentation. This paper summarises the key technological issues these diagnostics arising from the nuclear environment, recent progress and outstanding R&D for each system.

Details

Original languageEnglish
Pages (from-to)780-786
JournalJournal of Nuclear Materials
Volume417
Issue number1-3
DOIs
Publication statusPublished - 1 Feb 2011
EventICFRM14 2009 - 14th International Conference on Fusion Reactor Materials - Japan - IAEA, Sapporo, Japan
Duration: 7 Sep 200912 Sep 2009

Keywords

  • ITER, diagnostics, radiation effects

ID: 193230