Occupational doses for the first and second operators in lebanese interventional cardiology suites

Research output: Contribution to journalArticle

Authors

Institutes & Expert groups

Documents & links

DOI

Abstract

The study monitored occupational dose for 12 interventional cardiologists (first operators) and 10 technicians (second operators), from 10 different Lebanese hospitals performing coronary angiography and precutaneous coronary interventions exclusively on adult patients. Each individual wore dosemeters under and over the lead apron at chest and collar level, respectively, on the wrist and next to the left eye. The total follow-up period for each first/second operator varied between two to six bimonthly monitoring periods. For the first operator, the mean (range) effective, hand and eye lens doses were of 6 (1–41), 112 (10–356) and 15 (5–47) μSv/procedure, respectively. These were of 2.3 (0.1–8), 16 (2–109) and 7 (2–14) μSv/procedure for the second operator. Extrapolated annual eye lens doses revealed that both first and second operators may exceed 3/10th of the annual eye lens dose permissible limit thus supporting the need for dedicated eye lens monitoring

Details

Original languageEnglish
Pages (from-to)438-447
Number of pages10
JournalRadiation Protection Dosimetry
Volume182
Issue number4
DOIs
StatePublished - 2 Dec 2018

Keywords

  • staff dosimetry, interventional radiology, eye lens doses

ID: 5194130