Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens — results of the EURALOC study

Research output: Contribution to journalArticle

Standard

Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens — results of the EURALOC study. / Domienik-Andrzejewska, Joanna; Ciraj-Bjelac, Olivera; Askounis, Panagiotis; Covens, Peter; Dragusin, Octavian; Jacob, Sophie; Farah, Jad; Gianicolo, Emilio; Padovani, Renato; Teles, Pedro Peixoto; Widmark, Anders; Struelens, Lara.

In: Journal of Radiological protection, Vol. 38, No. 3, 01.09.2018, p. 934–950.

Research output: Contribution to journalArticle

Harvard

Domienik-Andrzejewska, J, Ciraj-Bjelac, O, Askounis, P, Covens, P, Dragusin, O, Jacob, S, Farah, J, Gianicolo, E, Padovani, R, Teles, PP, Widmark, A & Struelens, L 2018, 'Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens — results of the EURALOC study', Journal of Radiological protection, vol. 38, no. 3, pp. 934–950. https://doi.org/10.1088/1361-6498/aac64b

APA

Domienik-Andrzejewska, J., Ciraj-Bjelac, O., Askounis, P., Covens, P., Dragusin, O., Jacob, S., ... Struelens, L. (2018). Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens — results of the EURALOC study. Journal of Radiological protection, 38(3), 934–950. https://doi.org/10.1088/1361-6498/aac64b

Vancouver

Domienik-Andrzejewska J, Ciraj-Bjelac O, Askounis P, Covens P, Dragusin O, Jacob S et al. Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens — results of the EURALOC study. Journal of Radiological protection. 2018 Sep 1;38(3):934–950. https://doi.org/10.1088/1361-6498/aac64b

Author

Domienik-Andrzejewska, Joanna ; Ciraj-Bjelac, Olivera ; Askounis, Panagiotis ; Covens, Peter ; Dragusin, Octavian ; Jacob, Sophie ; Farah, Jad ; Gianicolo, Emilio ; Padovani, Renato ; Teles, Pedro Peixoto ; Widmark, Anders ; Struelens, Lara. / Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens — results of the EURALOC study. In: Journal of Radiological protection. 2018 ; Vol. 38, No. 3. pp. 934–950.

Bibtex - Download

@article{ec3033a7e06b4c159d281654034375ea,
title = "Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens — results of the EURALOC study",
abstract = "This paper investigates over five decades of work practices in interventional cardiology, with an emphasis on radiation protection. The analysis is based on data from more than 400 cardiologists from various European countries recruited for a EURALOC study and collected in the period from 2014 to 2016. Information on the types of procedures performed and their annual mean number, fluoroscopy time, access site choice, x-ray units and radiation protection means used was collected using an occupational questionnaire. Based on the specific European data, changes in each parameter have been analysed over decades, while country-specific data analysis has allowed us to determine the differences in local practices. In particular, based on the collected data, the typical workload of a European cardiologist working in a haemodynamic room and an electrophysiology room was specified for various types of procedures. The results showed that when working in a haemodynamic room, a transparent ceiling-suspended lead shield or lead glasses are necessary in order to remain below the recommended eye lens dose limit of 20 mSv. Moreover, the analysis revealed that new, more complex cardiac procedures such as chronic total occlusion, valvuloplasty and pulmonary vein isolation for atrial fibrillation ablation might contribute substantially to annual doses, although they are relatively rarely performed. The results revealed that considerable progress has been made in the use of radiation protection tools. While their use in electrophysiology procedures is not generic, the situation in haemodynamic procedures is rather encouraging, as ceiling-suspended shields are used in 90{\%} of cases, while the combination of ceiling shield and lead glasses is noted in more than 40{\%} of the procedures. However, we find that still 7{\%} of haemodynamic procedures are performed without any radiation protection tools.",
keywords = "interventional cardiology, radiation protection, work practice of interventional cardiologists, fluoroscopy, access routes",
author = "Joanna Domienik-Andrzejewska and Olivera Ciraj-Bjelac and Panagiotis Askounis and Peter Covens and Octavian Dragusin and Sophie Jacob and Jad Farah and Emilio Gianicolo and Renato Padovani and Teles, {Pedro Peixoto} and Anders Widmark and Lara Struelens",
note = "Score=10",
year = "2018",
month = "9",
day = "1",
doi = "10.1088/1361-6498/aac64b",
language = "English",
volume = "38",
pages = "934–950",
journal = "Journal of Radiological protection",
issn = "0952-4746",
publisher = "IOP - IOP Publishing",
number = "3",

}

RIS - Download

TY - JOUR

T1 - Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens — results of the EURALOC study

AU - Domienik-Andrzejewska, Joanna

AU - Ciraj-Bjelac, Olivera

AU - Askounis, Panagiotis

AU - Covens, Peter

AU - Dragusin, Octavian

AU - Jacob, Sophie

AU - Farah, Jad

AU - Gianicolo, Emilio

AU - Padovani, Renato

AU - Teles, Pedro Peixoto

AU - Widmark, Anders

AU - Struelens, Lara

N1 - Score=10

PY - 2018/9/1

Y1 - 2018/9/1

N2 - This paper investigates over five decades of work practices in interventional cardiology, with an emphasis on radiation protection. The analysis is based on data from more than 400 cardiologists from various European countries recruited for a EURALOC study and collected in the period from 2014 to 2016. Information on the types of procedures performed and their annual mean number, fluoroscopy time, access site choice, x-ray units and radiation protection means used was collected using an occupational questionnaire. Based on the specific European data, changes in each parameter have been analysed over decades, while country-specific data analysis has allowed us to determine the differences in local practices. In particular, based on the collected data, the typical workload of a European cardiologist working in a haemodynamic room and an electrophysiology room was specified for various types of procedures. The results showed that when working in a haemodynamic room, a transparent ceiling-suspended lead shield or lead glasses are necessary in order to remain below the recommended eye lens dose limit of 20 mSv. Moreover, the analysis revealed that new, more complex cardiac procedures such as chronic total occlusion, valvuloplasty and pulmonary vein isolation for atrial fibrillation ablation might contribute substantially to annual doses, although they are relatively rarely performed. The results revealed that considerable progress has been made in the use of radiation protection tools. While their use in electrophysiology procedures is not generic, the situation in haemodynamic procedures is rather encouraging, as ceiling-suspended shields are used in 90% of cases, while the combination of ceiling shield and lead glasses is noted in more than 40% of the procedures. However, we find that still 7% of haemodynamic procedures are performed without any radiation protection tools.

AB - This paper investigates over five decades of work practices in interventional cardiology, with an emphasis on radiation protection. The analysis is based on data from more than 400 cardiologists from various European countries recruited for a EURALOC study and collected in the period from 2014 to 2016. Information on the types of procedures performed and their annual mean number, fluoroscopy time, access site choice, x-ray units and radiation protection means used was collected using an occupational questionnaire. Based on the specific European data, changes in each parameter have been analysed over decades, while country-specific data analysis has allowed us to determine the differences in local practices. In particular, based on the collected data, the typical workload of a European cardiologist working in a haemodynamic room and an electrophysiology room was specified for various types of procedures. The results showed that when working in a haemodynamic room, a transparent ceiling-suspended lead shield or lead glasses are necessary in order to remain below the recommended eye lens dose limit of 20 mSv. Moreover, the analysis revealed that new, more complex cardiac procedures such as chronic total occlusion, valvuloplasty and pulmonary vein isolation for atrial fibrillation ablation might contribute substantially to annual doses, although they are relatively rarely performed. The results revealed that considerable progress has been made in the use of radiation protection tools. While their use in electrophysiology procedures is not generic, the situation in haemodynamic procedures is rather encouraging, as ceiling-suspended shields are used in 90% of cases, while the combination of ceiling shield and lead glasses is noted in more than 40% of the procedures. However, we find that still 7% of haemodynamic procedures are performed without any radiation protection tools.

KW - interventional cardiology

KW - radiation protection

KW - work practice of interventional cardiologists

KW - fluoroscopy

KW - access routes