Performance of potentiometric oxygen sensors with LSM-GDC composite electrode in liquid LBE at low temperatures

Research output: Contribution to journalArticlepeer-review

Standard

Performance of potentiometric oxygen sensors with LSM-GDC composite electrode in liquid LBE at low temperatures. / Lim, Jun; Manfredi, Gabriele; Mariën, An; Van den Bosch, Joris; Schuurmans, Paul (Peer reviewer).

In: Sensors and Actuators B: Chemical, Vol. 188, 11.2013, p. 1048-1054.

Research output: Contribution to journalArticlepeer-review

Bibtex - Download

@article{b1bd2fefbe314d3394db4676ca34695e,
title = "Performance of potentiometric oxygen sensors with LSM-GDC composite electrode in liquid LBE at low temperatures",
abstract = "Potentiometric oxygen sensors integrated with LSM-GDC composite electrode have been developed for use in liquid LBE at low temperatures. The performance of these sensors has been evaluated in oxygen saturated LBE. Their performance was compared with that for platinum electrode and Bi/Bi2O3 electrode. The sensor with LSM-GDC composite electrode performed well down to 200°C while those with platinum electrode and Bi/Bi2O3 electrode showed significant deviations at 200°C.",
keywords = "Potentiometric oxygen sensor, LSM-GDC composite electrode, Lead-Bismuth eutectic, MYRRHA",
author = "Jun Lim and Gabriele Manfredi and An Mari{\"e}n and {Van den Bosch}, Joris and Paul Schuurmans",
note = "Score = 10",
year = "2013",
month = nov,
doi = "10.1016/j.snb.2013.08.017",
language = "English",
volume = "188",
pages = "1048--1054",
journal = "Sensors and Actuators B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",

}

RIS - Download

TY - JOUR

T1 - Performance of potentiometric oxygen sensors with LSM-GDC composite electrode in liquid LBE at low temperatures

AU - Lim, Jun

AU - Manfredi, Gabriele

AU - Mariën, An

AU - Van den Bosch, Joris

A2 - Schuurmans, Paul

N1 - Score = 10

PY - 2013/11

Y1 - 2013/11

N2 - Potentiometric oxygen sensors integrated with LSM-GDC composite electrode have been developed for use in liquid LBE at low temperatures. The performance of these sensors has been evaluated in oxygen saturated LBE. Their performance was compared with that for platinum electrode and Bi/Bi2O3 electrode. The sensor with LSM-GDC composite electrode performed well down to 200°C while those with platinum electrode and Bi/Bi2O3 electrode showed significant deviations at 200°C.

AB - Potentiometric oxygen sensors integrated with LSM-GDC composite electrode have been developed for use in liquid LBE at low temperatures. The performance of these sensors has been evaluated in oxygen saturated LBE. Their performance was compared with that for platinum electrode and Bi/Bi2O3 electrode. The sensor with LSM-GDC composite electrode performed well down to 200°C while those with platinum electrode and Bi/Bi2O3 electrode showed significant deviations at 200°C.

KW - Potentiometric oxygen sensor

KW - LSM-GDC composite electrode

KW - Lead-Bismuth eutectic

KW - MYRRHA

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/ezp_130609

UR - http://knowledgecentre.sckcen.be/so2/bibref/10510

U2 - 10.1016/j.snb.2013.08.017

DO - 10.1016/j.snb.2013.08.017

M3 - Article

VL - 188

SP - 1048

EP - 1054

JO - Sensors and Actuators B: Chemical

JF - Sensors and Actuators B: Chemical

SN - 0925-4005

ER -

ID: 217618