Results of the EURADOS 2017 intercomparison for whole body neutron dosemeters (IC2017n)

Research output: Contribution to journalArticlepeer-review

Standard

Results of the EURADOS 2017 intercomparison for whole body neutron dosemeters (IC2017n). / Mayer, Sabine; Chevallier, Marie-Anne; Fantuzzi, Elena; Hajek, Michael; Luszik-Bhadra, Marlies; Tanner, Rick; Thomas, David; Vanhavere, Filip.

In: Radiation Measurements, Vol. 135, 106364, 23.04.2020, p. 1-4.

Research output: Contribution to journalArticlepeer-review

Harvard

Mayer, S, Chevallier, M-A, Fantuzzi, E, Hajek, M, Luszik-Bhadra, M, Tanner, R, Thomas, D & Vanhavere, F 2020, 'Results of the EURADOS 2017 intercomparison for whole body neutron dosemeters (IC2017n)', Radiation Measurements, vol. 135, 106364, pp. 1-4. https://doi.org/10.1016/j.radmeas.2020.106364

APA

Mayer, S., Chevallier, M-A., Fantuzzi, E., Hajek, M., Luszik-Bhadra, M., Tanner, R., Thomas, D., & Vanhavere, F. (2020). Results of the EURADOS 2017 intercomparison for whole body neutron dosemeters (IC2017n). Radiation Measurements, 135, 1-4. [106364]. https://doi.org/10.1016/j.radmeas.2020.106364

Vancouver

Mayer S, Chevallier M-A, Fantuzzi E, Hajek M, Luszik-Bhadra M, Tanner R et al. Results of the EURADOS 2017 intercomparison for whole body neutron dosemeters (IC2017n). Radiation Measurements. 2020 Apr 23;135:1-4. 106364. https://doi.org/10.1016/j.radmeas.2020.106364

Author

Mayer, Sabine ; Chevallier, Marie-Anne ; Fantuzzi, Elena ; Hajek, Michael ; Luszik-Bhadra, Marlies ; Tanner, Rick ; Thomas, David ; Vanhavere, Filip. / Results of the EURADOS 2017 intercomparison for whole body neutron dosemeters (IC2017n). In: Radiation Measurements. 2020 ; Vol. 135. pp. 1-4.

Bibtex - Download

@article{03768077b8d74224a97a159014b74a8d,
title = "Results of the EURADOS 2017 intercomparison for whole body neutron dosemeters (IC2017n)",
abstract = "The European Radiation Dosimetry Group (EURADOS) has set up intercomparison exercises for personal dosemeters on a regular basis. In 2017, the second EURADOS intercomparison for neutron dosemeters (IC2017n) took place. The intercomparison concerned the performance of neutron dosemeters provided by individual monitoring services to measure neutron personal dose equivalent, Hp(10). The irradiations, which included exposures to neutrons and mixed fields of neutrons and photons as commonly encountered in workplaces, were performed in accredited irradiation facilities in terms of Hp(10). The range of energies used in the intercomparison extended from thermal to several MeV, with different dose values and angles used. The paper reports on the results of this intercomparison for whole body neutron dosemeters.",
keywords = "Neutron dosimetry, Neutron personal dosemeter, EURADOS, Intercomparison, Track detector, Albedo dosemeter",
author = "Sabine Mayer and Marie-Anne Chevallier and Elena Fantuzzi and Michael Hajek and Marlies Luszik-Bhadra and Rick Tanner and David Thomas and Filip Vanhavere",
note = "Score=10",
year = "2020",
month = apr,
day = "23",
doi = "10.1016/j.radmeas.2020.106364",
language = "English",
volume = "135",
pages = "1--4",
journal = "Radiation Measurements",
issn = "1350-4487",
publisher = "Elsevier",

}

RIS - Download

TY - JOUR

T1 - Results of the EURADOS 2017 intercomparison for whole body neutron dosemeters (IC2017n)

AU - Mayer, Sabine

AU - Chevallier, Marie-Anne

AU - Fantuzzi, Elena

AU - Hajek, Michael

AU - Luszik-Bhadra, Marlies

AU - Tanner, Rick

AU - Thomas, David

AU - Vanhavere, Filip

N1 - Score=10

PY - 2020/4/23

Y1 - 2020/4/23

N2 - The European Radiation Dosimetry Group (EURADOS) has set up intercomparison exercises for personal dosemeters on a regular basis. In 2017, the second EURADOS intercomparison for neutron dosemeters (IC2017n) took place. The intercomparison concerned the performance of neutron dosemeters provided by individual monitoring services to measure neutron personal dose equivalent, Hp(10). The irradiations, which included exposures to neutrons and mixed fields of neutrons and photons as commonly encountered in workplaces, were performed in accredited irradiation facilities in terms of Hp(10). The range of energies used in the intercomparison extended from thermal to several MeV, with different dose values and angles used. The paper reports on the results of this intercomparison for whole body neutron dosemeters.

AB - The European Radiation Dosimetry Group (EURADOS) has set up intercomparison exercises for personal dosemeters on a regular basis. In 2017, the second EURADOS intercomparison for neutron dosemeters (IC2017n) took place. The intercomparison concerned the performance of neutron dosemeters provided by individual monitoring services to measure neutron personal dose equivalent, Hp(10). The irradiations, which included exposures to neutrons and mixed fields of neutrons and photons as commonly encountered in workplaces, were performed in accredited irradiation facilities in terms of Hp(10). The range of energies used in the intercomparison extended from thermal to several MeV, with different dose values and angles used. The paper reports on the results of this intercomparison for whole body neutron dosemeters.

KW - Neutron dosimetry

KW - Neutron personal dosemeter

KW - EURADOS

KW - Intercomparison

KW - Track detector

KW - Albedo dosemeter

UR - https://ecm.sckcen.be/OTCS/llisapi.dll/open/38902463

U2 - 10.1016/j.radmeas.2020.106364

DO - 10.1016/j.radmeas.2020.106364

M3 - Article

VL - 135

SP - 1

EP - 4

JO - Radiation Measurements

JF - Radiation Measurements

SN - 1350-4487

M1 - 106364

ER -