The challenges in the estimation of the effective dose when wearing radioprotective garments

Research output: Contribution to journalArticlepeer-review

Standard

The challenges in the estimation of the effective dose when wearing radioprotective garments. / Saldarriaga Vargas, Clarita; Struelens, Lara; Vanhavere, Filip.

In: Radiation Protection Dosimtery, Vol. 178, No. 1, 01.01.2018, p. 101-111.

Research output: Contribution to journalArticlepeer-review

Bibtex - Download

@article{11067d66a16e4405af18a0c644b52ec5,
title = "The challenges in the estimation of the effective dose when wearing radioprotective garments",
abstract = "The performance of a single or double dosimetry (SD or DD) algorithm on estimating effective dose wearing radioprotective garments (ERPG) depends on the specific irradiation conditions. This study investigates the photon energies and angles of incidence for which the estimation of ERPG with the personal dose equivalents measured over and under the RPG (Ho and Hu) becomes more challenging. The energy and angular dependences of ERPG, Ho and Hu were Monte Carlo calculated for photon exposures. The personal dosimeter of SCK•CEN was modelled and used to determine Ho and Hu. Different SD and DD algorithms were tested and critical exposure conditions were identified. Moreover, the influence of calibration methods was investigated for the SCK•CEN dosimeter when worn over RPG. We found that the accuracy with which ERPG is calculated using SD and DD is strongly dependent on the energy and angle of incidence of photons. Also, the energy of the photon beam used to calibrate the Ho dosimeter can bias the estimation of ERPG.",
keywords = "effective dose, lead apron, personal dosimetry, interventional procedures, radiation protection",
author = "{Saldarriaga Vargas}, Clarita and Lara Struelens and Filip Vanhavere",
note = "Score=10",
year = "2018",
month = jan,
day = "1",
doi = "10.1093/rpd/ncx081",
language = "English",
volume = "178",
pages = "101--111",
journal = "Radioation Protection Dosimitry",
issn = "0144-8420",
publisher = "Oxford University Press",
number = "1",

}

RIS - Download

TY - JOUR

T1 - The challenges in the estimation of the effective dose when wearing radioprotective garments

AU - Saldarriaga Vargas, Clarita

AU - Struelens, Lara

AU - Vanhavere, Filip

N1 - Score=10

PY - 2018/1/1

Y1 - 2018/1/1

N2 - The performance of a single or double dosimetry (SD or DD) algorithm on estimating effective dose wearing radioprotective garments (ERPG) depends on the specific irradiation conditions. This study investigates the photon energies and angles of incidence for which the estimation of ERPG with the personal dose equivalents measured over and under the RPG (Ho and Hu) becomes more challenging. The energy and angular dependences of ERPG, Ho and Hu were Monte Carlo calculated for photon exposures. The personal dosimeter of SCK•CEN was modelled and used to determine Ho and Hu. Different SD and DD algorithms were tested and critical exposure conditions were identified. Moreover, the influence of calibration methods was investigated for the SCK•CEN dosimeter when worn over RPG. We found that the accuracy with which ERPG is calculated using SD and DD is strongly dependent on the energy and angle of incidence of photons. Also, the energy of the photon beam used to calibrate the Ho dosimeter can bias the estimation of ERPG.

AB - The performance of a single or double dosimetry (SD or DD) algorithm on estimating effective dose wearing radioprotective garments (ERPG) depends on the specific irradiation conditions. This study investigates the photon energies and angles of incidence for which the estimation of ERPG with the personal dose equivalents measured over and under the RPG (Ho and Hu) becomes more challenging. The energy and angular dependences of ERPG, Ho and Hu were Monte Carlo calculated for photon exposures. The personal dosimeter of SCK•CEN was modelled and used to determine Ho and Hu. Different SD and DD algorithms were tested and critical exposure conditions were identified. Moreover, the influence of calibration methods was investigated for the SCK•CEN dosimeter when worn over RPG. We found that the accuracy with which ERPG is calculated using SD and DD is strongly dependent on the energy and angle of incidence of photons. Also, the energy of the photon beam used to calibrate the Ho dosimeter can bias the estimation of ERPG.

KW - effective dose

KW - lead apron

KW - personal dosimetry

KW - interventional procedures

KW - radiation protection

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/27781582

U2 - 10.1093/rpd/ncx081

DO - 10.1093/rpd/ncx081

M3 - Article

VL - 178

SP - 101

EP - 111

JO - Radioation Protection Dosimitry

JF - Radioation Protection Dosimitry

SN - 0144-8420

IS - 1

ER -