The surgeon's real dose exposure during balloon kyphoplasty procedure and evaluation of the cement delivery system: a prospective study

Research output: Contribution to journalArticle

Authors

Institutes & Expert groups

Documents & links

Abstract

Balloon kyphoplasty is a minimally invasive spinal surgery associated with significant radiation exposure for both patient and surgeon. We present here a way to considerably reduce the amount of radiation received by the surgeon during this procedure using a new injection system: the Cement Delivery System (CDS). The radiation dose to the fingers, wrists and legs was reduced by more than 80% when using the CDS.

Details

Original languageEnglish
Pages (from-to)1758-1764
JournalEuropean Spine Journal
Volume22
Issue number8
DOIs
Publication statusPublished - 30 Jan 2013

Keywords

  • extremity doses, spinal surgery