Where is the best position to place a dosemeter in order to assess the eye lens dose when lead glasses are used?

Research output: Contribution to journalSpecial issue

Standard

Where is the best position to place a dosemeter in order to assess the eye lens dose when lead glasses are used? / Honorio da Silva, Edilaine; Struelens, Lara; Covens, Peter; Ueno, Satoshi; Ube, Michiko; Vanhavere, Filip; Buls, Nico.

In: Radiation Measurements, Vol. 106, 01.11.2017, p. 257-261.

Research output: Contribution to journalSpecial issue

Author

Honorio da Silva, Edilaine ; Struelens, Lara ; Covens, Peter ; Ueno, Satoshi ; Ube, Michiko ; Vanhavere, Filip ; Buls, Nico. / Where is the best position to place a dosemeter in order to assess the eye lens dose when lead glasses are used?. In: Radiation Measurements. 2017 ; Vol. 106. pp. 257-261.

Bibtex - Download

@article{8078ea297c684216b3dd28eca54b7a31,
title = "Where is the best position to place a dosemeter in order to assess the eye lens dose when lead glasses are used?",
abstract = "The objective of this study was to evaluate the feasibility of assessing the eye lens dose when lead glasses are used, by attaching a small radiophotoluminescent (RPL) glass dosemeter to the lead glasses. RPL dosemeters were placed over and under the shielding of the glasses and their response was evaluated for a range of parameters, including irradiations in a standard X-ray beam and Monte Carlo simulations of a cardiac/radiologic intervention (scattered beam). For the specific situations taken into account in this study, the optimal position was found to be a dosemeter placed close to the bridge of the lead glasses, over its shielding.",
keywords = "eye lens dosimetry, radiophotoluminescence, interventional cardiology/radiology, lead glasses",
author = "{Honorio da Silva}, Edilaine and Lara Struelens and Peter Covens and Satoshi Ueno and Michiko Ube and Filip Vanhavere and Nico Buls",
note = "Score=30",
year = "2017",
month = "11",
day = "1",
language = "English",
volume = "106",
pages = "257--261",
journal = "Radiation Measurements",
issn = "1350-4487",
publisher = "Elsevier",

}

RIS - Download

TY - JOUR

T1 - Where is the best position to place a dosemeter in order to assess the eye lens dose when lead glasses are used?

AU - Honorio da Silva, Edilaine

AU - Struelens, Lara

AU - Covens, Peter

AU - Ueno, Satoshi

AU - Ube, Michiko

AU - Vanhavere, Filip

AU - Buls, Nico

N1 - Score=30

PY - 2017/11/1

Y1 - 2017/11/1

N2 - The objective of this study was to evaluate the feasibility of assessing the eye lens dose when lead glasses are used, by attaching a small radiophotoluminescent (RPL) glass dosemeter to the lead glasses. RPL dosemeters were placed over and under the shielding of the glasses and their response was evaluated for a range of parameters, including irradiations in a standard X-ray beam and Monte Carlo simulations of a cardiac/radiologic intervention (scattered beam). For the specific situations taken into account in this study, the optimal position was found to be a dosemeter placed close to the bridge of the lead glasses, over its shielding.

AB - The objective of this study was to evaluate the feasibility of assessing the eye lens dose when lead glasses are used, by attaching a small radiophotoluminescent (RPL) glass dosemeter to the lead glasses. RPL dosemeters were placed over and under the shielding of the glasses and their response was evaluated for a range of parameters, including irradiations in a standard X-ray beam and Monte Carlo simulations of a cardiac/radiologic intervention (scattered beam). For the specific situations taken into account in this study, the optimal position was found to be a dosemeter placed close to the bridge of the lead glasses, over its shielding.

KW - eye lens dosimetry

KW - radiophotoluminescence

KW - interventional cardiology/radiology

KW - lead glasses

UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/28484112

M3 - Special issue

VL - 106

SP - 257

EP - 261

JO - Radiation Measurements

JF - Radiation Measurements

SN - 1350-4487

ER -